EcoSolar Energy Conscious Design Limited
51
•
Replace cylinder sacrificial anodes
•
Clean out strainers
•
Check pump and differential controller
Glazing maintenance
The glazing will require periodic cleaning, ensure you have a suitable standing area, that will
not become wet during cleaning or if it does, will not endanger. Clean during cool times of
the day so the glass is not hot. Hose off, clean with a brush using simple green or similar and
rinse off again.
During the life of the collector, the glazing may be damaged and require replacement. This
can be a difficult and hazardous task if undertaken on the roof and so under most
circumstances the collector would be removed from the roof to have its glazing replaced.
The actual replacement of the glazing is a relatively easy task, aluminium extrusions clip on to
secure the glazing in place with a “U” shaped EPDM seal.
Lever off and unclip the four outer perimeter extrusions using an approximately 75mm wide
lever, once removed the glazing can be lifted off. Clean the collector absorber, leave to dry or
moisture has entered the collector and replace the glass.
System handover
Before handing over the system the installer much check and ensure that all requirements have been
met and the full installation is tested and commissioned. This shall include the water and electrical
systems.
The owner shall be provided with the relevant instructions and shall be instructed on the correct
operation and support required to obtain the most benefit from their installation.
The owner shall also be provided with copies of;
•
Installation sizing / survey
•
Installation inspection report
•
Operating and maintenance instructions
•
Manufacturers information
•
Recommended maintenance check list