4
SPECIFICATIONS
Rated capacity ±10%, m
3
/h
12
Feed water flowrate @ 0,2-0,4 MPa, m
3
/h
16-20
Water use per rinse, L
130
Power consumption, kW
11
Dimensions (W×D×H), m
4,2
×
1,4
×
2,1
Maximum dry weight, kg
1000
Connection port sizes
feed water
DN65
permeate
DN50
concentrate
DN65
Drain flow rate, m
3
/h
4
…
8
Recycle flow rate, m
3
/h
10…1
4
Permeate flow rate, m
3
/h
12…16
LIMITATIONS
2
Hardness
150 mg/L CaCO
3
Iron
0,1 mg/L
Manganese
0,05 mg/L
Silicate
20 mg/L
Total dissolved solids
3000 mg/L
Chemical oxygen demand
4,0 mg/L O
2
Residual chlorine
0,1 mg/L
Hydrogen sulfide
none
2
the limitations may be exceeded if using antiscalant, oxygen
scavenger, or other RO chemical pretreatment
Inlet pressure
0,2…0,4 MPa
Temperature of water
10…25 °C
Electrical power
400 V, 50 Hz 3-phase
Membrane pressure