19
INSTRUCTION MANUAL ECOSOFT
®
MEDIA SYSTEMS
Make sure all external cables are routed through guides in control valve backplates, so the
front panel can be put back on. Plug both power supplies in mains to power up the system.
8
. Enter programming menu and setup both control valves for Duplex operation (see
programming instructions in the next section).
9
. Start manual regeneration of the first filter by holding REGEN button for 5 seconds.
Scroll regeneration to backwash if it isn’t the 1st step of the sequence. When the control
valve starts the backwash, turn on mains water supply slightly at first. Air will be displaced
from the system via drain line while the pressure tank is being filled with water. When the
tank is full, water will start flowing down the drain line.
At this point, scroll through the rest of the regeneration sequence to end regeneration.
Then start manual regeneration of the second filter and scroll to backwash if it isn’t the 1st
step. Wait until all air is displaced from the second tank. Then scroll through the rest of
regeneration sequence to end regeneration.
Fully open mains water supply. Carefully inspect the system for leaks. Manually initiate two
more complete regenerations of each filter, one after the other.