![EcoSmart ECO-3Mini Instruction Manual Download Page 13](http://html.mh-extra.com/html/ecosmart/eco-3mini/eco-3mini_instruction-manual_2355326013.webp)
13
3-4
Mode Setting
DI Mode
:
(1) OFF
:
DI deactivated
(2) Button: ECOIR DI can connect external button which manually control
A/C power on/off or cool/fan.
(3) Motion
:
According to people motion, PIR controls A/C.
DI Reference: Advanced application. If DI mode turn motion and DI reference turn on,
PIR control becomes one of condition. PIR and temp. control power are the condition.
DO Mode
:
(1) IR + Relay: Infrared and relay are controlled together.
(2) IR Only: Only infrared is controlled.
(3) Relay Only: Only relay is controlled.
(4) IR + Relay0
:
Infrared and relay0 (control power) are controlled
together. Relay1 (control fan / cool)
Control Delay Time: Set ECO-IR to delay working by 0~10 second.
DI Mode: Motion- Delay close power
Idle time: Last cool mode time. If PIR didn’t detect people motion, idle time can
delay turning fan mode.
Fan time: Last fan mode time. If PIR didn’t detect people motion, fan time can delay
turning fan mode.
Fan & Cool based on power: Default: ON. This function is avoiding abnormal
operation because some of air conditioners cool/fan infrared code have power
infrared code.