Page 1: ...Design Great British DESICCANT DEHUMIDIFIER DH3511 MANUAL 110V 50Hz ...

Page 2: ...onsible for their safety Children should be supervised to ensure that they do not play with the appliance Disconnect from the mains when not in use Thank you for choosing this innovative dehumidifier This manual describes the many benefits and advanced features that this unique product has to offer This dehumidifier is a tough industrial unit designed to be used almost anywhere that dry air is req...

Page 3: ...ected Should it be necessary to replace this plug at any time it must be done by a qualified electrician Warning Never operate this appliance if it has a damaged cord or plug If the cord is damaged an approved service representative or a similar qualified person must replace it in order to avoid any hazards There should be direct access to the electrical plug after connecting the power Do not use ...

Page 4: ...mbranes absorb almost all of the moisture creating an extremely dry air stream this air stream is discharged directly through the Dry Air Out duct A second fan pushes a separate air stream Regen Air In through a heater bank Regen Heater where it s temperature is raised This air is then channelled back through a section of the rotor As this air passes back through the membranes its higher temperatu...

Page 5: ...e Coefficient heaters are based on a semi conductor that changes resistance as it becomes hotter The semi conductor is designed so that it s resistance rises rapidly at a predesignated temperature thus it maintains this temperature across a wide range of operational conditions This characteristic means that the heating element can never over heat to hazardous temperatures even if the regen airflow...

Page 6: ...to be dried Optionally the inlet may also be ducted to the room with the unit to give a re circulation effect In this case however because the unit uses a portion of the inlet air for regeneration provision must be made in the inlet duct to also draw air form outside the room Note As the Wet Air Out discharge is warm and very humid ensure it is directed where it will have no adverse effect on the ...

Page 7: ...humidistat via the Remote Humidistat Connector which can be accessed by removing the dust cap A connection plug is available on request ATTENTION The remote connector is mains voltage The remote switch humidistat should be connected between pins 1 and 3 The earth pin is connected to ground and can be used if required see wiring diagram The Remote Humidistat switch should be set to the ON position ...

Page 8: ...flow Check inlet air filter Check inlet outlets not obstructed Check ductwork if fitted is not obstructed Check voltage level Check fan is working If the unit is noisy Check fan operation Check rotor drive Check for loose screws Low Dehumidifying Effect Check airflows Check Amps reading Check rotor is turning Low Amps Reading Check Regen airflow Check Over Heat Protector Check Heater bank Rotor No...

Page 9: ... has been running without inlet air filter it can be cleaned by vacuum cleaner or low pressure compressed air OVER HEAT PROTECTOR In the event of total airflow loss the over heat protector will operate If this happens it will need to be manually re set after the airflow is restored To reset push the red button R down DESICCANT ROTOR DRIVE The desiccant rotor is driven by a geared motor via a tooth...

Page 10: ... temperature range 20C 40C Noise level 58dB IP rating IPx2 Dimensions l x w x h cm 56 0 x 35 2 x 34 5 Weight net kg 20 5 TECHNICAL DATA Subject to modifications without prior notice Available from your supplier Flexible ducting Ø80mm 3 or 6m Flexible ducting Ø125mm 3 or 6m High voltage humidistat 5m connecting cable and standard screw plug connected Reticulated foam filter pack of 3 OPTIONAL PARTS...

Page 11: ...K BRN G Y REGEN FAN PROCESS FAN REMOTE CONNECTOR L MAIN SWITCH N M PROCESS FAN ROTOR DRIVER HEATER BANK REMOTE HUMIDISTAT SWITCH 1 3 REMOTE SWITCH HUMIDISTAT OPTIONAL FAN CAPACITOR OVERHEAT PROTECTION MANUAL RESET HOUR METER E E REGEN FAN AMMETER FAN CAPACITOR M M WIRING DIAGRAM AND SCHEMATIC DIMENSIONS PROCESS AIR OUT Ø 125mm REGEN AIR IN Ø 80mm PROCESS AIR IN Ø 125mm WET AIR OUT Ø 80mm 35 2 mm 3...

Page 12: ...Subject to modifications Ecor Pro Ampèrestraat 18J 3861 NC Nijkerk The Netherlands Tel 31 297 52 75 83 www ecorpro eu info ecorpro eu ...