8
TECHNICAL DATA
Model
D850E
D950E
Mains
220–240 V / 50 Hz
Power consumption
W
970
1250
Current (
operation
)
A
4.3
5.6
Current (
at start
)
A
20
22
Water extraction
at
30 °C, 70 % RH
30 °C, 80 % RH
32 °C, 90 % RH
L/24h
52
60
63
61
76
81
IP code
IP24
IP24
Refrigerating agent R290*
g
300
300
Airflow (
at high fan speed
)
m
3
/h
500
680
Operating temperature
°C
7 – 35
Dimensions
w x h x d
mm
660 x 750 x 345
Weight (
net
)
kg
37
39
The room must have a minimum floor area of 15m
2
Made in P.R.C. Specifications may change without prior notice.
TROUBLE SHOOTING
If the dehumidifier does not operate:
• Make sure the unit is plugged in.
• Ensure the humidistat control is turned on.
If the unit is noisy:
• Make sure the dehumidifier is standing solidly and level.
If the unit is leaking:
• Check the drainage tube for correct fitting.
• Check for twists and bends in the drainage tube.
• Check the drainage tube for a sufficient slope.
• Check and make sure that the outlet of the drainage pipe is not under the water-
level in the drain.
Disposal
Waste electrical and electronic products must not be disposed of with household waste.
This product should be taken to your local recycling centre for safe treatment.
GB
R290
brennbares
Naturgas