SETTINGS AND ADJUSTMENTS

The Gemini can be turned on or off, and adjusted, using 

either the included remote or the control panel on the front 

of the unit. Both the remote and the control panel buttons 

have the same functions.

Fan Speed

Power  

ON/OFF

Ions

Display Screen

Timer

Power ON/OFF

ActivePure

Timer

Fan Speed

Ions

Auto Mode

POWER (stand by)

 

Turns the unit ON and OFF. 

FAN SPEED 

Controls the fan speed and 

auto function setting. The 

color around the power 

button changes depending on 

fan speed: 

  • Quiet

 is green. 

  • Low

 is blue. 

  • Medium

 is orange. 

  • High

 is red.

AUTO MODE

This mode automatically sets 

the unit according to the 

air quality detected by the 

dust and gas/odor sensor. 
Ionization generator and 
ActivePure work together 

when the unit is in Auto 

Mode.

IONS

Indicates that ionization is 
working. The Ion button turns 
the ionizer on and off.

ACTIVEPURE

Indicates the photocatalytic 

purification is operating. The 

ActivePure mode starts and 

stops the ActivePure function. 

 UV LAMPS  

UV1 or UV2 will illuminate 

when the relative UV tube fails 

to work or needs replacing. 

The Display Screen is used to display all current settings (see 
page 4) as well as any maintenance reminders.

DISPLAY SCREEN 

Ions

Check Filter

ActivePure

TIMER

Indicates the automatic shut 

off is on. The timer count (1-12 
hours) is set with the Timer 

button. 

 

 CHECK FILTER 

Check Filter illuminates after 
an accumulative 3,000 hours 

of usage as a reminder to 

change the prefilter and 

activated carbon filter. The 

HEPA filter should also be 
checked against the color 

shades located on the frame 

to determine if replacement 

is needed. 

  DUST AND GAS  

Indicates the level of current 

air quality detected. The chart 

below shows the five quality 

levels that are displayed.

In Auto Mode, the unit 

automatically adjusts the 

fan speed to compensate for 

contaminant levels.

PLEASE NOTE 

- if there is no 

wavy line shown, dust and gas 

are below detectable levels.

Very 

Good

Good

Ordinary Poor

Dust Indicator

Timer

Fan Speed Settings

Gas Indicator

UV Replacement  
Indicator

Excellent

Summary of Contents for Gemini

Page 1: ...installation operation specifications features maintenance user guide read these instructions before use save this user guide ...

Page 2: ...th the HEPA filtration system and up to 1 500 sq ft of coverage of germ fighting ActivePure technology Depends on variables such as severity and frequency of pollution humidity and temperature Warranty Length of warranty will vary depending on model See warranty card for specific details SPECIFICATIONS This user guide is also available online at http www Ecoquest com ownersmanuals 1 Remove protect...

Page 3: ...n Buttons L Display M Remote Control Signal Receiver N Dust Sensor O Gas Sensor P Front Air Flow Inlet Q Remote Control Dust Gas Odor Sensors detect air quality Air quality levels are indicated by the unit s front display Auto Mode automatically adjusts fan speed to handle contaminants quickly ActivePure technology kills germs viruses and bacteria on surfaces in your environment including MRSA E c...

Page 4: ...e ActivePure mode starts and stops the ActivePure function UV LAMPS UV1 or UV2 will illuminate when the relative UV tube fails to work or needs replacing The Display Screen is used to display all current settings see page 4 as well as any maintenance reminders DISPLAY SCREEN Ions Check Filter ActivePure TIMER Indicates the automatic shut off is on The timer count 1 12 hours is set with the Timer b...

Page 5: ...usty or dirty environment more frequent cleaning may be necessary Remove dirt with a soft fiber cloth For tough dirt a neutral detergent is recommended NOTE Do not expose the housing to hard or sharp objects or abrasives Handle the front cover carefully when removing and replacing to avoid damage SENSORS Carefully vacuum any dust that has accumulated or that is blocking the sensor air inlets FILTE...

Page 6: ...s into place REPLACING UV TUBES FILTERS AND FRONT COVER 5 5 Place UV Lamps into holders and rotate either up or down to lock into place 6 6 Insert Compound Filter into the unit bottom first Gently push the top inward until it fits securely into place NOTE the HEPA filter should face towards the outside front of the unit 7 7 Insert Prefilter Secure by pulling out and turning the locks PRESS PRESS P...

Page 7: ...ke sure the front cover is secure Check or replace the batteries in the Remote Control 2 Air is not blowing out of unit Make sure there is nothing blocking or covering the air inlets or air outlet 3 Unit is not performing as expected Make sure the unit is not placed in a poor ventilated environment or blocked by other objects Make sure filters are clean and do not need to be changed 4 Air outlet s...

Page 8: ... be effective for one 1 year from the date of original purchase of this unit excluding filters UV lamps and photocatalyst or 90 days from date of purchase for Remote Control All implied warranties including warranties of merchantability and fitness for a particular purpose are limited to the term of the express warranty granted herein However some states do not allow limitations on how long an imp...

Reviews: