ECOPURE EPWUFF Installation And Operation Manual Download Page 6

6

Installation Instructions

To Disconnect Tubing:
1

. Push the collet inward and hold with a finger while pulling the tubing out.

tubing

collet (depress to remove tubing)

end of tubing round and smooth,

with no cuts, nicks or flat spots

correct full 3/4" engagement

Tubing correctly cut and connected

Incorrect partial engagement

Remove and discard foam plugs

foam plug

push in fitting

continued from the previous page

Connect Tubing:
1

. Use a tube cutter to cut the end of tubing square.

2

. Inspect the end (about 1") of the tubing to be sure there are no nicks, scratches or other rough spots.

If needed cut the tubing again.

3

. Push tubing through the collet and all the way into fitting.  Full engagement is 3/4" length of tube into

the fitting.

FIG. 4

FIG. 5

Step D - Turn On Water, Check for Leaks and Rinse Carbon Fines

1

. Open the shutoff valve(s) that you closed at the beginning of this installation.

2

. Open the filtered water faucet to purge air from the system.  When the water runs smooth, with no

bubbles or spurting, close faucet and check installation for leaks.

3

. Open the filtered water faucet and let water run for 10 minutes to rinse out carbon fines.

Step C - Install the Filter Cartridge

1

. Remove the small plastic shipping cap from the open end of the filter cartridge.

2

. Install the cartridge onto the water filter head assembly, as shown in Figure 6. Turn cartridge to the

right to tighten.

Summary of Contents for EPWUFF

Page 1: ...etails 201 8401220 Rev 02 1 2 18 Installation and Operation Manual If you have any questions or concerns when installing operating or maintaining your water filtration system call our toll free number...

Page 2: ...in use in the United States or Canada General Provisions The above warranties are effective provided the Undersink Full Flow Water Filtration System is operated at water pres sures not exceeding 100 p...

Page 3: ...adhered to Consult with your licensed plumber q The undersink full flow water filtration system works on water pressures of 30 psi minimum to 100 psi maximum If your house water pressure is over the m...

Page 4: ...adaptor Slotted and Phillips screwdrivers Pliers and adjustable jaw wrench Tubing cutter Electric drill Teflon tape FIG 2 NOTE Be sure to allow a minimum space of 1 1 2 under the system for removing...

Page 5: ...ittings is shown in Figure 3 1 Close the sink s water shut off valve s or another shut off valve upstream from where you will install the filter and open faucets to relieve pressure from the sink s co...

Page 6: ...d cut the tubing again 3 Push tubing through the collet and all the way into fitting Full engagement is 3 4 length of tube into the fitting FIG 4 FIG 5 Step D Turn On Water Check for Leaks and Rinse C...

Page 7: ...rms to NSF ANSI 42 and 53 for the specific performance claims as verified and substan tiated by test data The rated capacity for this system is 2000 gallons 7570 liters at a rated service flow of 2 0...

Page 8: ...orrection Remove rough portion reinsert tubing into fitting Parts List 2 1 3 7 4 5 9 6 8 Parts Bag To order repair parts call toll free 1 800 693 1138 Please purchase replacement cartridges from the r...

Reviews: