ECOPURE EPWUFF Installation And Operation Manual Download Page 4

1"

4

Parts & Tools

Typical Undersink Installation

Locate the water filter housing on the cold water supply pipe, under the kitchen and/or bathroom sink, to

filter the cold water.  Refer to the following drawing.

=

Filter head, bracket & mounting screws

=

Filter cartridge

=

Tubing

=

Faucet adaptor

=

Slotted and Phillips screwdrivers

=

Pliers and adjustable jaw wrench

=

Tubing cutter

=

Electric drill

=

Teflon tape

FIG. 2

NOTE:

Be sure to allow a minimum space of 1-1/2” under the

system for removing the filter cartridge to change it.

1”

mounting

screws (2)

3/8” tubing

to faucet

OUTLET

blue collar on

push-in fitting

INLET

yellow collar on

push-in fitting

3/8” tubing

from cold

water supply

SINK

HOT

COLD

shutoff valve

filtered water

faucet

OUTLET

INLET

Included:

Not Included:

Summary of Contents for EPWUFF

Page 1: ...etails 201 8401220 Rev 02 1 2 18 Installation and Operation Manual If you have any questions or concerns when installing operating or maintaining your water filtration system call our toll free number...

Page 2: ...in use in the United States or Canada General Provisions The above warranties are effective provided the Undersink Full Flow Water Filtration System is operated at water pres sures not exceeding 100 p...

Page 3: ...adhered to Consult with your licensed plumber q The undersink full flow water filtration system works on water pressures of 30 psi minimum to 100 psi maximum If your house water pressure is over the m...

Page 4: ...adaptor Slotted and Phillips screwdrivers Pliers and adjustable jaw wrench Tubing cutter Electric drill Teflon tape FIG 2 NOTE Be sure to allow a minimum space of 1 1 2 under the system for removing...

Page 5: ...ittings is shown in Figure 3 1 Close the sink s water shut off valve s or another shut off valve upstream from where you will install the filter and open faucets to relieve pressure from the sink s co...

Page 6: ...d cut the tubing again 3 Push tubing through the collet and all the way into fitting Full engagement is 3 4 length of tube into the fitting FIG 4 FIG 5 Step D Turn On Water Check for Leaks and Rinse C...

Page 7: ...rms to NSF ANSI 42 and 53 for the specific performance claims as verified and substan tiated by test data The rated capacity for this system is 2000 gallons 7570 liters at a rated service flow of 2 0...

Page 8: ...orrection Remove rough portion reinsert tubing into fitting Parts List 2 1 3 7 4 5 9 6 8 Parts Bag To order repair parts call toll free 1 800 693 1138 Please purchase replacement cartridges from the r...