Installation Instructions

Step B - Make Tubing Connections

NOTE: Remove protective foam plugs before connecting tubes (See Fig. 4).  Discard foam plugs.
1

. Locate the piece of supplied 3/8" tubing not used previously.  Route it between the union connector

and the filter system outlet (See Figures 2 & 3).  Allowing some slack, measure and cut to length.  Cut

the ends of the tubing square.

2

. Insert tubing all the way into the union connector and filter system outlet.  Pull on the tubing to be

sure that it's held firmly in the fittings.

3

. Repeat steps 1 and 2 to connect the tube installed on the cold water shutoff to the filter system inlet.

Tubing Connection (all push-in fitting locations):

This system includes push-in fittings for quick tubing connections.  When working with the fittings, do the

following.

continued on the next page

Step A - Install Water Supply Fittings

Check and 

comply with local plumbing codes

as you plan, then install the fittings to connect the

undersink filter into the sink’s cold water supply line.  Fittings (9/16-24 thread) and 3/8” O.D. tubing are

included to provide connections to and from the undersink filter’s inlet and outlet.  A typical connection

using the included water supply fittings is shown in Figure 3.

1

Close the sink’s water shut off valve

(s), or another shut off valve upstream from where you will

install the filter, 

and open faucets

to relieve pressure from the sink’s cold water supply line.

2

. Locate the line connecting the cold water shutoff to the sink faucet.  Typically this line will be a flexible

hose.  Disconnect the nut that connects this line to the cold water shutoff.  Use a bucket to catch water

that drains from this line.

3

. Locate one piece of the supplied 3/8” tubing, plus the supplied compression nut, ferrule and tubing

insert (See Fig. 3).  Assemble the parts onto the tube, as shown in Figure 3, and thread the compres-

sion nut onto the cold water shutoff.  Tighten to provide a leak-tight connection.

4

. Locate the water supply adaptor (supplied) and, using thread sealing tape, install it into the nut on the

supply line which you disconnected in Step 2.  Refer to Figure 3.

5

. Press the stem of the water supply adaptor into one end of the supplied union connector (See Figure

3).  Be sure to push the stem all the way in.

insert

ferrule

compression

nut

3/8" tubing to

water filter

INLET

use thread

sealing tape

on threads

cold water shutoff

filter system assembly

cold water

shutoff

SINK

filtered water faucet

OUTLET

INLET

water supply

adaptor

flexible connection

to faucet

use thread sealing

tape on threads

3/8" tubing from

water filter

OUTLET

union

connector

FIG. 3

Summary of Contents for EPWUFF

Page 1: ...etails 201 8401220 Rev 02 1 2 18 Installation and Operation Manual If you have any questions or concerns when installing operating or maintaining your water filtration system call our toll free number...

Page 2: ...in use in the United States or Canada General Provisions The above warranties are effective provided the Undersink Full Flow Water Filtration System is operated at water pres sures not exceeding 100 p...

Page 3: ...adhered to Consult with your licensed plumber q The undersink full flow water filtration system works on water pressures of 30 psi minimum to 100 psi maximum If your house water pressure is over the m...

Page 4: ...adaptor Slotted and Phillips screwdrivers Pliers and adjustable jaw wrench Tubing cutter Electric drill Teflon tape FIG 2 NOTE Be sure to allow a minimum space of 1 1 2 under the system for removing...

Page 5: ...ittings is shown in Figure 3 1 Close the sink s water shut off valve s or another shut off valve upstream from where you will install the filter and open faucets to relieve pressure from the sink s co...

Page 6: ...d cut the tubing again 3 Push tubing through the collet and all the way into fitting Full engagement is 3 4 length of tube into the fitting FIG 4 FIG 5 Step D Turn On Water Check for Leaks and Rinse C...

Page 7: ...rms to NSF ANSI 42 and 53 for the specific performance claims as verified and substan tiated by test data The rated capacity for this system is 2000 gallons 7570 liters at a rated service flow of 2 0...

Page 8: ...orrection Remove rough portion reinsert tubing into fitting Parts List 2 1 3 7 4 5 9 6 8 Parts Bag To order repair parts call toll free 1 800 693 1138 Please purchase replacement cartridges from the r...

Reviews: