background image

18

FIG. 39

Broom

Handle

Pencil

Mark

1” - 2”

Salt
Salt

Bridge
Water

Level

Push Tool into

Salt Bridge to

Break

FIG. 40

Cap

O-ring Seal

Screen Support

Screen

Gasket

*Flow Plug (HVDC)

Housing

Ferrule

Nut

Cone Screen

*Flow Plug

*Install with lettered

side up, concave

side down.

CLEANING THE NOZZLE & VENTURI

A clean nozzle & venturi (See Figure 40) is a necessity

for the water softener to work properly.  This small

component creates the suction to move brine from the

brine tank, into the resin tank.  If it should become

plugged with sand, silt, dirt, etc., the water softener will

not work, and hard water will result.

Nozzle & Venturi Disc

IMPORTANT: Be sure small hole in the gasket is cen-

tered directly over the small hole in the nozzle & ven-

turi housing.  Be sure the numbers are facing up

Routine Maintenance

ADDING SALT

Slide open the salt lid and check the salt storage level

frequently.  If the water softener uses all the salt

before you refill it, you will experience hard water.

Until you have established a refilling routine, check the

salt every two or three weeks.  Always add if less than

1/4 full.  Be sure the brinewell cover is on.

NOTE:

In humid areas, it is best to keep the salt stor-

age level lower, and to refill more often to

avoid salt “bridging”.

Recommended Salt:

Nugget, pellet or coarse solar

salts with less than 1% impurities.

Salt Not Recommended:

Rock salt, high in impurities,

block, granulated, table, ice melting, ice cream making

salts, etc.

BREAKING A SALT BRIDGE

Sometimes, a hard crust or salt “bridge” forms in the

brine tank.  It is usually caused by high humidity or the

wrong kind of salt.  When the salt “bridges,” an empty

space forms between the water and the salt.  Then,

salt will not dissolve in the water to make brine.

Without brine, the resin bed is not recharged and hard

water will result.
If the storage tank is full of salt, it is difficult to tell if

you have a salt bridge.  A bridge may be underneath

loose salt.  Take a broom handle, or like tool, and hold

it next to the water softener.  Measure the distance

from the floor to the rim of the water softener.  Then,

gently push the broom handle straight down into the

salt.  If a hard object is felt before the pencil mark is

even with the top, it is most likely a salt bridge.  Gently

push into the bridge in several places to break it.  Do

not use any sharp or pointed objects as you may

puncture the brine tank.  Do not try to break the salt

bridge by pounding on the outside of the salt tank.

You may damage the tank.

To get access to the nozzle & venturi, remove the

water softener’s top cover.  Put the bypass valve(s)

into the bypass position.  Be sure the water softener is

in soft water (service) cycle (no water pressure at noz-

zle & venturi).  Then, holding the nozzle & venturi

housing with one hand, un screw the cap.  Do not lose

the o-ring seal.  Lift out the screen support and screen.

Then, remove the nozzle & venturi disc, gasket and

flow plug(s).  Wash the parts in warm, soapy water

and rinse in fresh water.  Be sure to clean both the top

and bottom of the nozzle & venturi disc.  If needed,

use a small brush to remove iron or dirt.  Do not

scratch, misshape, etc., surfaces of the nozzle & ven-

turi.
Gently replace all parts in the correct order.  Lubricate

the o-ring seal with silicone grease and locate in place.

Install and tighten the cap by hand, while supporting

the housing.  Overtightening may break the cap or

housing.  Put the bypass valve(s) into service (soft

water) position.
Recharge the softener to reduce water level in the

tank.  This will also assure that the softener is com-

pletely recharged and ready to provide softened water

again.  Check the water level in the tank by looking

down the brinewell.  If the water level does not drop

after a recharge, the problem has not been resolved.

Call 1-800-693-1138.

Summary of Contents for EP31

Page 1: ...ntaining your water softener call our toll free number 1 800 693 1138 or visit www ecopure com When you call please be prepared to provide the model and serial number of your product found on the rati...

Page 2: ...ides 4 Inspect Shipment 5 Water Conditioning Information 5 Installation Requirements 6 7 Installation Instructions 8 11 Programming the Water Softener 12 13 Customizing Features Options 14 17 Routine...

Page 3: ...Salt Dose The salt dose is selected by the electronic controls at regeneration time based on the amount needed These models are efficiency rated The efficiency rating is valid only at the minimum salt...

Page 4: ...known quality without adequate dis infection upstream or downstream of the system European Directive 2002 96 EC requires all electrical and electronic equipment to be disposed of accord ing to Waste E...

Page 5: ...water stands for a period of time the particles settle to the bottom of the container Generally these irons are removed from water by filtra tion Chlorination is also recommended for bacterial iron C...

Page 6: ...o condition all water in the home install the water softener close to the water supply inlet and upstream of all other plumbing connections except outside water pipes Outside faucets should remain on...

Page 7: ...r if desired parts for a 3 valve bypass system not included can be purchased and assembled as shown in Figure 8 Bypass valves allow you to turn off water to the softener for mainte nance if needed but...

Page 8: ...l of water and salt may cause the tank to fracture at the shim 2 Visually check and remove any debris from the water softener valve inlet and outlet ports 3 Make sure the turbine assembly spins freely...

Page 9: ...on the single bypass valve Make sure that the tabs are fully seated COMPLETE INLET AND OUTLET PLUMBING Measure cut and loosely assemble pipe and fittings from the main water pipe to the inlet and out...

Page 10: ...the main water supply valve Run water until there is a steady flow from the opened faucets with no air bubbles 4 Place bypass valve s in service or soft water posi tion as follows Single bypass valve...

Page 11: ...into the unit For this reason sanitizing as follows is suggested when installing 1 Slide open the salt lid remove the brinewell cover and pour about 3 oz 6 tablespoons of household bleach into the so...

Page 12: ...ead down sets the time back NOTE Press buttons and quickly release to slowly advance the display Hold the buttons down for fast advance 2 When the correct time is displayed press the SELECT button and...

Page 13: ...ater s hardness num ber press the SELECT button and the display will change to show the Recharge Time screen FIG 20 Programming the Water Softener SET RECHARGE REGENERATION START TIME If you completed...

Page 14: ...TONIGHT Press and release do not hold the REGENERATION button RECHARGE TONIGHT will begin flashing in the display and the softener will begin regeneration at the next preset recharge time 2 00 AM or a...

Page 15: ...s extra cleaning of the resin bed before it is regenerated with the salt brine To conserve water if your water supply does not contain iron or sedi ments be sure this feature is set to OFF The default...

Page 16: ...aximum between regenerations Default Display 6 Press SELECT again to display the 12 or 24 hr screen 12 OR 24 HOUR CLOCK All time displays are shown in standard clock time 1 to 12 AM and 1 to 12 PM at...

Page 17: ...e pretreatment filtration For problem water applications additional sediment filtration is recommended TANK LIGHT To turn on the light inside the salt storage tank press the TANK LIGHT button on the f...

Page 18: ...water will result If the storage tank is full of salt it is difficult to tell if you have a salt bridge A bridge may be underneath loose salt Take a broom handle or like tool and hold it next to the...

Page 19: ...en the salt lid and remove the softener s top cover Take off both drain hoses if they will inter fere with moving the softener into position over the drain 5 Carefully remove the large holding clips a...

Page 20: ...er Contact a licensed plumber 6 Brine float dirty or broken Clean or replace Brine Valve Float Assembly 7 Leak between valve and resin tank Replace o rings between resin tank and valve Water hard some...

Page 21: ...ttern OTHER INFORMATION While in the diagnostics screen the following information is available and may be beneficial for various reasons This information is retained by the electronic controller from...

Page 22: ...hining a flashlight into the brinewell and observing a noticeable drop in the liquid level 5 If the softener does not draw brine nozzle and or venturi dirty nozzle and venturi not seated properly on g...

Page 23: ...23 Notes...

Page 24: ...24 8 7 6 5 Rating Decal Location Softener Exploded View Valve Assembly See Pages 26 27 for parts 1 2 3 4 5 6 7 8 9 11 12 10 15 13 14 16 17 18 19 22 20 21 23 24 25 26 28 29 27 30...

Page 25: ...Ecodyne Water Systems 1890 Woodlane Drive Woodbury MN 55125 Not illustrated Softener Parts List Key No Part No Description 1 7351054 Power Supply 24V DC 2 7360825 Top Cover 3 7360833 Salt Lid order de...

Page 26: ...26 Valve Exploded View 50 52 53 51 55 56 59 58 57 60 61 66 67 62 63 64 68 69 70 71 75 65 76 77 79 78 80 81 82 Wear Strip Seal Cross section View 83 84 85 86 87 88 89 90 54 72 73 74...

Page 27: ...urbine Support Shaft 74 Turbine 75 7082053 Valve Body 76 7081201 Retainer Nozzle Venturi 77 7342649 O Ring 1 4 x 3 8 pack of 2 78 1202600 Nut Ferrule 7238450 Nozzle Venturi Assembly EP31 incl Key Nos...

Page 28: ...force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure to perform its warranty obligations is the result of strikes government regulation mat...

Reviews: