background image

English

Update 25/01/2017

TECHNICAL FEATURES C7931

 

General characteristics

Electric grey scissor-shaped multi-function table.

Standard upholstery dimensions: 62x200 cm (M47)

Recommended maximum weight: 200 Kg

Height variation: 52-106 cm
Electric motor-controlled height adjustable by side rails system.
Height adjustment without side misalignment

Steel frame with grey epoxy powder coating heated at 250°C
90 mm diameter steel legs. With 4 table levellers, one in each leg.
Retractable castors with foot lever.  Just for moving the table around, NOT intended for patient transportation.
Detachable chrome paper roll holder included as standard.

Standard headrest type T01 - Headrest with adjustable arm supports . Oval breather hole and bung included.
Set of folding armrests (non-removable)

Head-/Backrest adjustable by gas spring.
Central section adjustable by electric motor with hand control.
Feet section adjustable by gas spring.

Approx. weight: 85 Kg

Upholstery Features
Fire-resistant Class M2 artificial leather, EC compliant.
Sanitized® anti-microbial and antibacterial protection.
Available in 22 colours.
Foam thickness 4 cm.
Foam firmness III - Medium firm

 

Electric Motor Features
Stroke length: 300 mm
Asynchronous motor 1-230V. AC ±10%
Integrated thermal protection
Max. Power: 8000N - Average speed at load 0: 14mm/s
Voltage: 230V/50-60 Hz - Power consumption: 3,7A
Working cycle: 25s non stop / 400s off
Safety class: I - Standard protection: IP44
EMI (electromagnetic interference) Directive compliant

Secondary Motor Features
Stroke length: 100 mm
Asynchronous motor 1-230V. AC ±10%
Integrated thermal protection
Max. Power: 4000N - Average speed at load 0: 6mm/s
Voltage: 230V/50-60 Hz - Power consumption: 1,5A
Working cycle: 25s non stop / 400s off
Safety class: II - Standard protection: IP44
EMI (electromagnetic interference) Directive compliant

Summary of Contents for C7931

Page 1: ...ILLA EL CTRICA ELECTRIC TABLE TABLE LECTRIQUE INSTRUCCIONES INSTRUCTIONS Leer antes de utilizar por primera vez Read carefully before the first use A lire avant la premi re utilisation Actualizaci n 2...

Page 2: ...repuesto del fabricante para cada modelo en concreto Todo accesorio parte o pieza debe encajarse y colocarse de acuerdo con las instrucciones del fabricante Los componentes ajenos podr an resultar pe...

Page 3: ...r de subida o bajada hasta conseguir la altura deseada Atenci n NO PISAR no es un pedal En las camillas con estructura tipo tijera cuando sube o baja sin peso puede notarse una vibraci n que no indica...

Page 4: ...mportar la anulaci n de la garant a En caso de mal funcionamiento contacten con Ecopostural o con su distribuidor d Tapicer a Se recomienda quitar el polvo con un trapo h medo Cuando no sea suficiente...

Page 5: ...rse de manera diferente con respecto a los residuos urbanos Una vez transcurrida su vida til deber depositarse en un centro de recogida espec fica La separaci n de desechos de productos usados y embal...

Page 6: ...Espa ol 6...

Page 7: ...dulo central regulable mediante motor el ctrico con mando de mano M dulo de la parte pies regulable mediante pist n hidr ulico Peso aproximado 85 Kg Caracter sticas del Tapizado Tapizado en polipiel i...

Page 8: ...ould be fitted or fixed in according to the special manufacturer s instructions Any spare replacement component part different to the manufacturer s could be dangerous for the people involved in the t...

Page 9: ...or down without any load This vibration does not mean the table to be abnormal Caution Safely position patient before table height adjustment Do not insert hands feet or garments into the moving part...

Page 10: ...ulation will invalidate the guarantee If any malfunction or failure is suspected contact immediately Ecopostural or the reseller d Upholstery A wet cloth should be enough to do the dusting Anyway if t...

Page 11: ...t to a specific EC Directive and it must be followed accordingly as shown by the crossed skip symbol Therefore at the end of its useful life you will have to apply to a specialized waste disposal cent...

Page 12: ...English 12...

Page 13: ...by gas spring Central section adjustable by electric motor with hand control Feet section adjustable by gas spring Approx weight 85 Kg Upholstery Features Fire resistant Class M2 artificial leather EC...

Page 14: ...fectueuses ou us es doivent tre remplac es imm diatement par des pi ces de rechange provenant du fabricant d origine pour chaque mod le de table Tout accessoire pi ce ou partie enti re doit s emboite...

Page 15: ...h rique est une barre situ e autour de la base de la table Pour changer la hauteur d placer la barre l g rement droite ou gauche avec le pied Attention NE JAMAIS appuyer sur la barre ce n est pas une...

Page 16: ...ulez pas le v rin hydraulique et ou lectrique car cela entrainerait l annulation imm diate de la garantie En cas de mauvais fonctionnement ou panne veuillez contactez imm diatement Ecopostural ou votr...

Page 17: ...te aux les d chets urbains A la fin de sa vie utile cet appareil doit tre d pos dans un centre de tri des d chets pour un recyclage ad quat qui respecte l environnement et la sant La collecte s par e...

Page 18: ...Fran ais 18...

Page 19: ...laqu avec peinture gris poxy cuite au four 250 C Pieds de 90 mm de diam tre Avec 4 vis de compensation de sol une sous chaque pied Roulettes escamotables actionnement par p dale pour d placement vide...

Page 20: ...rge 0 14mm s Voltage 230V 50 60 Hz Consommation lectrique 3 7A Cycle de travail 25s en continu 400s en arr t Norme de s curit I Protection standard IP44 Conforme la directive europ enne en mati re de...

Page 21: ...Fran ais R vision 25 01 2017...

Reviews: