ELECTRIC TABLE
INSTRUCTIONS
Ecopostural thanks you for buying our products. The item you have just purchased has been
manufactured according to high quality and security standard. Follow the below-mentioned instructions
carefully in order to be able to make use of it for a long time. Click on to the TECHNICAL INFORMATION
section in our website www.ecopostural.com
* Our company will decline any responsibility for any damage occurred if ignoring these
instructions.
1) GENERAL INSTRUCTIONS
- Please read carefully the operating and safety instructions before using our products. These instructions
must be adhered to. Keep the instructions booklet for further check-ups.
- Familiarize yourself with the precise use of the item.
- If the table is handled by unqualified people in an inappropriate way or not according to the intended
purpose, the use of the examination table may be dangerous. Be careful when handling the table as there
is a risk of being trapped by the mobile parts and because of sudden movements.
- Regularly check the table entirely to find any sign of malfunction or damage. Periodically check mains
cable and plug. We recommend to handle them with the utmost care and to avoid the bending of the
cables.
- Worn or damaged pieces must be solely replaced by original pieces by the manufacturer depending on
the table model.
- All components parts or accessories should be fitted or fixed in according to the special manufacturer’s
instructions. Any spare / replacement component part different to the manufacturer’s could be dangerous
for the people involved in the table handling.
* Notice: The use of non original pieces or the alteration of the item will incur in a loss of validity of
the manufacturer’s guarantee, instructions and Declaration of Conformity.
2) OPERATING INSTRUCTIONS
a) Installing
The table must lean on a solid and level ground.
Notice: in certain floor surfaces the table legs might leave marks after a prolonged contact. Check the
technical specifications of the floor manufacturer to avoid any trouble.
In order to move the table around, you will need to release the castors by pressing the locking levers
downwards. To lock the castors, simply lift both locking levers upwards with your foot.
These castor wheels are only suitable for moving the table around when required (maintenance...), NOT
intended for patient transportation.
* Caution: Before the patient lies down make sure the castors are locked.
b) Load capacity
This item has been tested to support a MAXIMUM STATIC WEIGHT of 135 Kg evenly distributed all over.
* In case this weight is exceeded a safety device will automatically start-up. As a result the table might
gradually move downwards regardless of the motor activation. Reduce the load in order to restore the
proper operation of the table.
Absolutely avoid leaning on the very edge for support as it may tilt over.
If pressure on a reduced area exceeds the allowed weight, the table upholstery could split up. Keep the