9
Inspect all of the components that you received with your unit. You should have received the
following:
1.
ecoPlus™ Media Tank
2.
ecoPlus™ Valve Head w/ Upper Screen
3.
Riser Tube (shipped inside #1)
4.
Mounting Bracket
5.
Cartridge Filter Housing Cap
6.
Cartridge Filter Housing Sump
7.
Sediment Pre-Filter (shipped inside #3)
8.
Bypass Assembly
9.
Inlet Assembly
10.
Outlet Assembly
11.
Spanner Wrench
12.
Flexible Stainless Steel Connectors
13.
Small Parts Bag
(8 Lag Bolts and 8 Washers)
14.
Bridge Assembly
15.
ecoTAC™ Media Tank and Valve
16. Undebed Gravel (Media #1)
17. KDF 55 (Media #2)
18. Coconut Shell Carbon (Media #3)
19. Catalytic Carbon (Media #4)
19. Inert Beads (Media #5)
21. Media Funnel
22. Dust Mask (not shown)
Step 2. – Selecting an Installation Location
While exterior installation in warm climate areas is possible, we strongly recommend interior
installation only. The system cannot be allowed to freeze or severe system damage could
occur. The system should not be exposed to rain and it should not be installed in direct
sunlight, as long-term exposure to UV light could damage components of the system.
Select a location for installation of your water filter that is within close proximity to the main
incoming water line of the home. The location should have a firm, level surface with enough
space for the unit itself and sufficient space surrounding the unit to facilitate maintenance.
The approximate minimum installation space required for
this model is:
34” Wide x 60” High x 21.5” Deep
In most cases, the system should be installed after the
branch line(s) to exterior irrigation, unless you want your
exterior faucets to deliver treated water. Depending on
the configuration of your plumbing system, this is not
always possible. ecoPLUS™ should be installed after
your pressure tank and booster pump, if applicable, and
before your hot water heater.