OPERATING CONDITIONS
The following chart provides guidance on the conditions required for successful operation of
your ecoPLUS™ system.
This water treatment system is designed specifically for the treatment of chlorinated city
water supplies. ecoPLUS™ is not intended to be used to treat water from private wells or
private surface water sources.
If you are unsure of the status of your water supply, please
contact your dealer for assistance.
USE OF THIS EQUIPMENT OUTSIDE OF THESE OPERATING CONDITIONS MAY
ADVERSELY AFFECT THE PERFORMANCE OF YOUR SYSTEM, RESULT IN SYSTEM
DAMAGE INCLUDING WATER LEAKS AND CORRESPONDING PROPERTY DAMAGE, AND
MAY VOID YOUR WARRANTY.
It is very important to note that the presence of elevated levels of chlorine, iron, manganese,
hydrogen sulfide, copper, and certain other contaminants can damage the TAC media,
reducing its effectiveness and shortening its life.
WATER EXCEEDING ANY OF THE FOLLOWING LEVELS SHOULD BE PRE-TREATED TO
REDUCE CONTAMINANT LEVELS BELOW THE STATED LEVEL:
Iron
0.3 ppm (mg/l)
Manganese
0.05 ppm (mg/l)
Copper
1.3 ppm (mg/l)
Hydrogen Sulfide
Must be removed
Polyphosphates
Must be removed
Oils
Must be removed
The presence of these contaminants in municipally treated (city) water is very rare, with the
exception of copper which can be found in homes with newly installed copper pipes.