Page 19
OMNI by EconoHeat
Symptom
Cause
Remedy
8. Proper draft setting
cannot be achieved
♦
Negative dr
t in building
or exhaust
ans present
♣
Excessive ash buildup
♦
May need to install power vent/dr
t inducers in stack
see
igure 2
or wiring)
♣
Clean ash and soot
rom combustion chamber and heat
exchangers
9. Poor or reduced heat
production
♦
Flame too small
♣
Entir
uel supply may be
plugged
•
Excessive ash buildup
exchangers
•
Through vision port, check
lame to see i
lame is
smaller than usual or too
large and uncontrolled
♦
Nozzle or preheater block may be plugged with carbon
debris
♣
Clean
r, both oil strainer and check oil pump screen
•
Clean ash
rom combustion chamber and exchangers
OWH-75 Ten (10) Year Limited Warranty
EconoHeat (manufacturer) warrants to the purchaser of Unit Heaters listed above will be free
from defects in materials and workmanship for the durations speciied below, which duration
begins on the date of delivery to the customer. Customer is responsible for maintaining proof
of date of delivery.
If return is deemed necessary for warranty evaluation and determination of repair or
replacement, unit heater is to be sent to the factory with freight prepaid. EconoHeat reserves
the right to determine appropriate action for repair or replacement.
No parts will be accepted by EconoHeat without RA# (return authorization number) clearly marked
on outside of shipping package. Obtaining RA# requires model and serial numbers, description
of part being replaced and nature of defect. Call factory to receive RA#.
Warranty Covers:
• Combustion chamber and heat exchanger ten (10) years limited, full repair or replacement
(parts only), irst three (3) fullly covered / last seven (7) 50% coverage
• Oil heater block, twenty (20) years (parts only)
• Oil heater block controller PCB, three (3) years (parts only)
• All other components, one (1) year (parts only)
Troubleshooting Continued