9
®
Hang the waste disposer onto the sink flange
assembly (Fig. 1) and partially secure it by
turning the lower clamping bayonet (turn right
when viewed from below) using the supplied
„Z“ key (Fig. 2).
Turn the waste disposer with the drain hole and
installed waste pipe elbow towards you.
Screw the first part of the siphon onto the thread
of the waste elbow - the inlet pipe with the nut
and a seal (Fig. 3). Connect the „U“ part of the
siphon and the siphon outlet pipe.
Turn the waste disposer so that the outlet waste
pipe points towards to the opening of the main
waste pipe in the wall.
Connect the outlet waste pipe of the siphon to
the main waste pipe located in the wall.
Tighten all of the nuts of the siphon piping.
Fully tighten the clamping bayonet with a „Z“
key wrench to the locked position via the locking
latch (Fig. 2).
Siphon is not included as standard
We recommend using to facilitate installation
original accessories:
Waste pipe siphon 6/4“x 40 mm EAN code:
8595156224360.
1
Support sealing ring
(rubber insert)
Sink
Hladina vody
The upper part of the firmly attached
neck assembly
„Z“ key
Interconnection of clamping bayonets
1.
2.
Possibility of
shortening the
inlet and outlet
pipes by up to
4 cm
Waste
pipe
Waste elbow pipe
Inlet siphon pipe
„U“ pipe of the siphon
Outlet waste
pipe
Wall
Cut to shorten as required
1.
2.
3.
4.
1
3.
Connection to the mounting and siphon trap assembly
If your waste pipes are not completely new, this is now a good opportunity to clean your pipes from old deposits with a plumber‘s plume
or screw before connecting the waste disposer. This will prevent future complications.
NOTICE
Connecting the waste disposer
to the sink and siphon trap
For easier tightening, we recommend lightly lubricating the top of the rubber ring
with grease or soap.
Never lubricate the siphon traps gasket seals
Typical waste pipe connection
*
Optimal
distance
Sink
Sink
Water level
Water level
Water level
Longer
distance
Low
In the ground
**
Minimum
distance
Water level
Sink
Sink
Flooded grinding chamber
of the waste disposer
Typical waste pipe connection
Recommended distances between the outlet
waste pipe and sink bottom.
Optimal distance
–
applies to the original
siphon trap kit – EAN: 8595156224360
(Fig. 1).
*305-380 mm for model HEAVY DUTY
(without shortening the inlet pipe 340-380 mm).
Minimum distance
– reachable when
reversing the siphon trap outlet pipe
(Fig. 2).
**180 mm for model HEAVY DUTY
Correct siphon trap istallation
to the waste pipe show in
(Fig 1, 2, a 3.)
Incorrect siphon installation
– waste pipe
outlet must not be higher that the outlet of the
waste disposer
(Fig. 4).
The high water level within the grinding chamber
will cause a splash into the sink every time you
turn on the waste disposer. It will also cause
worse draining of the sink or when connecting
the dishwasher via the waste disposer
filling of the sink when draining with waste water.
We recommend using two separate siphon traps
for a double bowl sink. One siphon trap may
cause complications.
Ideal diameter of waste pipes is 40, 50 mm
and more. Length according to local standards.
Summary of Contents for DELUXE EVO3