![Ecom ECOM-D Operating Instructions Manual Download Page 22](http://html.mh-extra.com/html/ecom/ecom-d/ecom-d_operating-instructions-manual_2354712022.webp)
Page 22
ECOM-D
10. Adjustments
In addition to the ECOM-D functions described previously, various ad-
justments can be made to the instrument.
From the main menu, select
"Adjustments"
and confirm with
<En-
ter>
.
A selection of modifiable parameters, adjustable ac-
cording to the application, is displayed.
Place the cursor on the desired line and press
<En-
ter>
to view or modify the adjustment. The modifia-
ble parameters are:
Unit
(adjustment with
arrow keys
):
- Calculation of gas concentrations in:
- ppm
= volume concentration (parts per million)
- mg/m3
= mass concentration per volume unit
- mg/kWh (undiluted) = mass concentration per power unit
- mg/MJ (undiluted) = mass concentration per power unit
- ppm (undiluted) = volume concentration (parts per million)
- mg/m3 (undiluted) = mass concentration per volume unit
Undiluted
:
Conversion of the gas concentration on selected reference oxygen:
- mg/kWh and mg/MJ are always calculated on 0% O2 basis
- Conversion formula
O2 reference
(for ppm and mg/m3 - Input after pressing
<Enter>
):
- Input of O2 reference value O2 ref
E
ref
= E
meas
*
21 - O
2ref
21 - O
2meas
Einheit
Ref. O2
Fuel type
Air pressure
Set clock
Paper feed
Internal
Select
:
Adjustments