7
Water connection
Water is connected at location 15 on the drawing. The water is connected directly to the backflow
preventer (1). Use included barb connection if ¾” hose is used. Water pressure should not exceed 85 psi
at the inlet, as this is the max acceptable pressure of the pH control system (first part of the backboard).
Water purity should not exceed 80 TDS (total dissolved solids). Make sure the filter housing has a filter
installed.
S
ystem Water connection
The pH regulated water enters the system at this
location 8 (yellow arrow) and the final product (HOCl)
comes out at location 10 (green arrow) see picture 10.
The system located at position 9 on the overview can
either be a 240 or a 1200 unit. Which unit used depends
on the concentration and volume needed.
If the 240 unit is used, in and out locations are
switched. The E240 also uses push-fit connections.
The E240 has an internal Brine tank (NaCl) which needs
no additional setup. The E1200 uses an external brine tank which uses filter 13 in
picture 9, as a suction filter. The filter is lowered into the tank used for the brine.
Filter and additional hose is included in the system.
Additional information on the specific system can be found in the unit’s manual.
E1200 unit:
https://www.ecoloxtech.com/pdf/e1200soperationmanual.pdf
E240 unit:
http://ecoloxtech.com/pdf/e240soperationmanual.pdf
Power connection
Depending on what options have been chosen, the power is connected differently. The pH control part
of the setup does not use electrical power for its operation. The only power needed for operation is
therefore the E240/1200 unit. Both units connect directly to an outlet and are compatible with most
outlets around the world (100 – 230 Vac, 50/60Hz). Both have an on/off button on the side.
Level sensor / pump
With the addition of a level sensor the power connection is moved to the electrical box right over the
unit. Power cable comes with a US plug (US customers only) that goes into the electrical box and
distributes power from there. The power inlet cable is connected to a normal power outlet. Control box
is compatible with the same voltages as the systems. Customers outside the US will have to supply and
install a power plug that fits their region.
Picture 11
E
-
1200 in/
out-put
Picture 12
E
-
1200 unit,
brine filter