Z-Wave Command Class Basic 

For backwards compatibility with older Z-Wave Controllers, the Basic Command Class is supported in the following 

manner. If either a smoke alarm or a co alarm is detected, the lifeline nodes will receive an unsolicited Basic Report of 
0xFF. When no more smoke or co alarm sound detected, the lifeline nodes will receive an unsolicited Basic Report of 
0x00. The device has no functionality mapped to receiving a Basic Set command, and does not control devices with a 
Basic Set. 

 

Z-wave Command Class Multi Level Sensor

 

The FireFighter™ has a temperature sensor built into the device and can be queried on a Wake Up Notification with a 

Multi Level Sensor Get command. The sensor supports reporting both in Celsius and Fahrenheit.  

 
 
FCC COMPLIANCE STATEMENT

 

This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can 

radiate  radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to 

radio  communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause 

harmful  interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to 

try to  correct the interference by one or more of the following measures:

 

 

Re-orient or relocate the receiving antenna

 

 

Increase the separation between the equipment and receiver

 

 

Connect the equipment to an outlet on a different circuit from the receiver

 

 

Consult the dealer or an experienced radio/TV contractor for help.

 

 

WARNING: 

Changes or modifications not expressly approved by Encore Controls could void the user’s authority to operate the equipment.

 

 

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the 
following two conditions: (1) this device may not cause interference, and (2) this device must accept any 
interference, including interference that may cause undesired operation of the device.

 

 

C’et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est soumis aux deux conditions suivantes:

 

(1) c’et appareil ne peut pas provoquer d'interférences, et (2) c’et appareil doit accepter toute interférence, y compris les interférences qui peuvent

 

causer un mauvais fonctionnement de la dispositif.

 

 

 

FCC ID: XQC-FFZ5 IC: 9863B-FFZ5

 

 

 

 

The Firefighter

 detector does not detect the presence of smoke, heat, or fire directly. It relies solely on the presence of an audio alarm signal generated by an existing smoke or fire 

detector in proximity to the Firefighter™ detector to make such a determination. The Firefighter™ detector must be used with smoke detectors certified according to UL Standards, 
and in strict accordance with the installation and operation instructions provided with such detectors. It is the owner’s responsibility to ensure that smoke or fire detectors used in 
conjunction with the Firefighter™ detector are maintained and tested on a regular basis in accordance with the manufacturer’s instructions. Encore Controls  expressly disclaims any 
responsibility for the failure of the Firefighter™ detector to detect the presence of smoke or fire due to the failure of any smoke or fire detector used in conjunction with the 
Firefighter™ detector to operate properly due to any condition, including improper installation, operation,  maintenance or testing of such smoke or fire detector.

 

Summary of Contents for Firefighter FF-ZWAVE5

Page 1: ...atterymarch Park Quincy MA 02269 Printed information describing proper installation operation testing maintenance evacuation planning and repair service is to be provided with this equipment Warning Owner s instruction notice Not to be removed by anyone except occupant Adding Sensor A Be sure that the Z Wave Controller you are using is compatible with the FireFighter B Either mount or move the sen...

Page 2: ...alarm detection is activated The current mode is written to non volatile memory and will therefore persist on replacing the battery RED GREEN CO not reliably detected and battery will last twice as long RED RED GREEN CO is more reliably detected and battery will last half as long LED The Firefighter is equipped with a multi color LED When a valid audio signal is heard the LED will turn yellow and ...

Page 3: ...y awake while tampered for testing Z Wave command class functionality The following information is intended for software engineers working on Z Wave controllers and home automation enthusiasts to integrate the Z Wave FireFighter into their system Device Classes Generic Device Class GENERIC_TYPE_SENSOR_NOTIFICATION Specific Device Class SPECIFIC_TYPE_NOTIFICATION_SENSOR Command Classes COMMAND_CLAS...

Page 4: ... Sounding Event Inactive 0x00 Smoke Alarm Silent CO Alarm 0x02 Carbon Monoxide Detected Unknown Location 0x02 CO Alarm Sounding Event Inactive 0x00 CO Alarm Silent Home Security 0x07 Tampering Product Cover Removed 0x03 Case Tampered Event Inactive 0x00 Case Restored to Closed Position Power Management 0x08 Replace Battery Soon 0x0A Battery is Getting Low Replace Battery Now 0x0B Battery Needs Rep...

Page 5: ...m the receiver Consult the dealer or an experienced radio TV contractor for help WARNING Changes or modifications not expressly approved by Encore Controls could void the user s authority to operate the equipment This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device mus...

Page 6: ......

Reviews: