IMPORTANT

: This light fixture uses light emitting diodes (LEDs) to provide 

light. LEDs do not have a filament to burn out like a traditional light bulb. 

LEDs gradually emit less light over their lifetime, but will typically last 36,000 

hours in a residential environment.

Periodically clean the fixture and diffuser using a mild, non-abrasive cleaner 

and soft cloth. When cleaning the fixture, make sure the power is turned off. 

Do not spray cleaner directly onto any part of the fixture or LEDs.  

Care and Maintenance

Security Light Operation

The motion sensor on this fixture has a built in Dusk-to-Dawn sensor. The 

Dusk-to-Dawn sensor disables the motion sensor during daylight hours. The 

motion sensor will not activate during daylight hours regardless of motion detection.

Operating Instructions

MODE                                             TIMER KNOB                   WALL SWITCH                   SENSITIVITY KNOB

Test mode.                                     Test area.                         On.                                        Any setting.
AUTO motion sensor mode.       Timer area.                       On.                                        Any setting.
Manual “ON” mode.                    Timer area.                       Toggle OFF and ON           Any setting.

 

                                    within two seconds.

Return to AUTO motion               Timer area.                       On.                                       Any setting.

sensor mode 

                                      

- 4 -

- 4 -

The motion sensor must be tested before setting the 

time and sensitivity levels. The 

TEST

 option is located 

on the 

TIMER

 control knob on the underside of the 

sensor head. To test the fixture, switch the wall switch 

that controls power to the fixture to the ON position and 

turn the rotary knob to the “TEST” area. [The lights will 

come on for 40 seconds regardless of whether there is 

motion or not, and regardless of whether it is day or night.] Leave the rotary knob in 

the “TEST” area and test the sensitivity by crossing in the path of the sensor. The light 

will come on only if it senses movement. Once movement stops, it will turn off in 5 

seconds (

Fig. 1

). The test is now complete.

1

The control knob located on the opposite side is marked 

SENSITIVITY

, which determines the degree of motion 

detection. Rotating this knob clockwise raises the 

sensitivity of the motion sensor for up to 60 ft. of distance. 

Rotating the knob counterclockwise lowers the sensitivity 

down to as close as 5 ft. It may be necessary to adjust the 

“SENSITIVITY” knob several times until the proper setting 

is achieved (

Fig. 2

). NOTE: The higher sensitivity level increases the likelihood of a false 

activation being triggered. For maximum range performance, allow the fixture to operate 

in any setting (with power) for at least 48 hours.

2

The 180 degree coverage of the motion sensor is 

measured side to side (

Fig. 3

). Therefore, the sensor will 

better detect motion across the field of view 

(side-to-side), rather than motion coming straight at the 

sensor (in-and-out). Adjust the motion sensor head so 

that it detects motion moving across the coverage area. 

The position of the sensor head should not exceed 45 

degrees from horizontal (

Fig. 4

). Do not aim the motion 

sensor at a body of water, bushes or plants that may move in the wind, pedestrian 

traffic, moving cars, etc., as this will trigger the motion sensor. 

NOTE

: If the sensor 

arm becomes loose, it will not hold the sensor head at the proper angle. Readjust the 

sensor head and tighten the joint screw on the sensor arm.

3

Fig. 3

Fig. 4

Once the fixture has been tested for proper operation 

and sensitivity, rotate the rotary knob on the 

TIMER

 

control to the “TIMER”

 

area. The “TIMER” position 

allows the fixture to go into AUTO motion sensor mode. 

Rotating the knob clockwise increases the duration of 

light up to 5 minutes once motion is detected. Rotating 

the knob counterclockwise decreases the duration of 

light down to 10 seconds once motion is detected. It may be necessary to adjust the 

“TIMER” knob several times until the desired length of time is determined (

Fig. 5

).

To control the security light from inside the home, activate manual “ON” mode by 

toggling the wall light switch OFF and ON within 2 seconds. The security light will turn 

on and stay on for approximately 8 hours, or until the dusk-to-dawn sensor detects light 

in the morning. Once the dusk-to-dawn sensor detects light, the manual “ON” mode 

will automatically go back to its original settings of the AUTO motion sensor mode.

4

5

Fig. 1

Fig. 2

Fig. 5

45°

Summary of Contents for SE1039-TBZ-02LF0-E

Page 1: ... fuse panel before removing the old fixture or installing the new one LEDs can be damaged by electrostatic discharge ESD shock Before installation discharge yourself by touching a grounded bare metal surface to remove this hazard To avoid damage do not remove the clear lens over the LED module CAUTION DO NOT USE THIS FIXTURE WITH A DIMMING CIRCUIT If dimmer controls are present remove them and rep...

Page 2: ...ave mounted NOT suitable for ground mount installations 8 Do NOT allow the sensor head to touch the LED head housing Maintain at least 1 in spacing between the LED heads and the sensor head 9 For proper operation and protection against water damage the motion sensor head controls MUST be facing downward 10 Do NOT mount below 5 ft SAVE THESE INSTRUCTIONS IN A LOCATION CLOSE TO THE FIXTURE TO REFER ...

Page 3: ...store power to the electrical box at the circuit breaker or fuse panel Make sure the wall switch that controls the electrical box for your security light is returned to the ON position and check that your light is functioning properly If the light is functioning properly fit the silicone cap into the mounting screw opening to prevent water seepage into the housing Fig 8 Position the wall plate ove...

Page 4: ... up to 60 ft of distance Rotating the knob counterclockwise lowers the sensitivity down to as close as 5 ft It may be necessary to adjust the SENSITIVITY knob several times until the proper setting is achieved Fig 2 NOTE The higher sensitivity level increases the likelihood of a false activation being triggered For maximum range performance allow the fixture to operate in any setting with power fo...

Page 5: ...fferent location where it no longer causes reflected light Security light comes on for 2 Light is sensing motion in 1 Make sure the sensor is not picking on for no apparent reason the detection zone moving objects such as bushes at night trees traffic water etc 2 Test the motion sensor by covering up the front curved lens with a cardboard to block the view If the light turns off then something in ...

Page 6: ...et appareil doit accepter toute interférence reçue y compris les interférences pouvant entraîner un fonctionnement indésirable Français Consignes de sécurité importantes AVERTISSEMENT Afin de réduire les risques d INCENDIE DE CHOC ÉLECTRIQUE OU DE BLESSURE 1 Ne touchez PAS aux ampoules à DEL 2 Ne retirez PAS la lentille protectrice transparente des ampoules à DEL 3 Ne regardez PAS directement les ...

Page 7: ...tuées à l arrière de la tête de lampe autour du joint pivotant Fig 5 REMARQUE Serrez les vis avant d assujettir le luminaire au boîtier électrique Fig 7 45 45 Fig 8 7 Rétablissez l alimentation électrique de la boîte de jonction depuis le panneau de disjoncteurs ou de fusibles Assurez vous que l interrupteur mural contrôlant la boîte de jonction de votre luminaire de sécurité est à la position ON ...

Page 8: ... de commande de la minuterie TIMER sur le dessous de la tête du détecteur Pour tester le luminaire mettez l interrupteur mural qui contrôle l alimentation électrique du luminaire dans la position de marche ON et tournez le bouton rotatif jusqu à la zone TEST La lumière s allumera et restera allumée pendant 40 secondes qu il y ait des mouvements ou non et que ce soit le jour ou la nuit Laissez le b...

Page 9: ... la durée désirée ait été déterminée Fig 5 Pour contrôler l éclairage de sécurité depuis l intérieur de la résidence activez le mode manuel de marche ON en faisant basculer l interrupteur d éclairage mural entre les positions de marche et d arrêt dans un délai de deux secondes Le luminaire de sécurité s allumera et restera allumé pendant environ 8 heures ou jusqu à ce que le capteur crépusculaire ...

Page 10: ...uvement en couvrant la lentille courbée avec un carton pour bloquer la vue Si la lumière s éteint alors quelque chose dans la zone de détection active le capteur Réorientez le détechteur de mouvement ou modifiez la sensibilité la distance du capteur Guide de dépannage S il vous manque une pièce ou si vous avez des questions concernant l installation veuillez visiter notre site web au www goodearth...

Page 11: ...nte de los LED 3 NO mire directamente a los LED encendidos sin importar el lapso 4 NO toque opere ni instale la lámpara mientras esté en contacto con el agua 5 Requisitos eléctricos 120 V CA 60 Hz 0 31 A MÁX Conductores de electricidad para 90 mínimo 6 NO deje conductores desnudos expuestos fuera de la estructura de la base de la pared 7 Esta unidad es adecuada para instalación sobre cajas eléctri...

Page 12: ...e a un electricista calificado Hay un conductor de puesta a tierra verde de cobre previamente conectado al ensamble Si la caja eléctrica es de plástico o si en su interior tiene un conductor de puesta a tierra de cobre desnudo o de color verde el conductor de puesta a tierra del ensamble y el de la caja eléctrica deben empalmarse con uno de los empalmes plásticos pequeños se incluyen Fig 3 Si la c...

Page 13: ...use cinta aislante para asegurar los empalmes plásticos en los terminales de los conductores Empuje el exceso de conductores hacia la caja eléctrica 2 Fig 2 Fig 3 GND FRO NT FRO NT GND Fig 6 45 Coloque la placa para pared sobre la placa de montaje de modo que el orificio central de la placa para pared se alinee con el orificio central en la placa de montaje Mientras sujeta la placa para pared en s...

Page 14: ...e se logre el ajuste adecuado Fig 2 NOTA El nivel de sensibilidad más alto aumenta la probabilidad de que se cause una activación falsa Para lograr un rendimiento de rango máximo deje funcionar la lámpara en cualquier modo con alimentación durante al menos 48 horas 2 La cobertura de 180 grados del detector de movimiento se mide lado a lado Fig 3 Por lo tanto el sensor detectará mejor el movimiento...

Page 15: ...er está defectuoso al Servicio al Cliente La luz de seguridad 1 El sensor anochecer 1 Cambie la posición del cabezal de luz cambia de encendido a amanecer está detectando para apuntar la luz lejos de apagado continuamente luz reflejada de la luz superficies que reflejan luz de seguridad 2 Pongo un pedazo pequeño de cinta aislante negra sobre el control del sensor anochecer amanecer 3 Cambie la lám...

Page 16: ...lés La responsabilidad del fabricante se limita en todos los casos al reemplazo de la lámpara defectuosa El fabricante no será responsable de ninguna otra pérdida daño costos de mano de obra o lesiones causadas por el producto Esta limitación de la responsabilidad del fabricante incluye toda pérdida daño costos de mano de obra o lesión I que involucre a una persona o propiedad u otros casos II que...

Reviews: