OPERATIONAL START-UP & CHECK:
Before proceeding with start-up, verify the following:
1. Open the doors and verify that the pump intake strainer is correctly installed in the sump.
2. Check that the upper and lower rinse arms are securely screwed into their receptacles.
3. Check that the plugs are securely screwed into the ends of both wash arms and the rinse arms.
4. Check that the wash arms are securely screwed into the stationary bases and that they rotate freely.
5. Verify that the drain stopper is correctly installed at the drain seat.
QUICK START GUIDE:
After the initial installation of the machine:
1. Insert chemical feeder pump stiffeners into appropriate containers.
2. Turn on machine.
POWER UP:
To energize electrically, proceed as follows:
A. Turn on electrical power supply at the circuit breaker.
B. Check voltage at incoming terminals L1, L2 & L3. The voltage measured at these points should match data plate voltage.
C. If voltages are in required range, close the control box cover.
3. Before enabling the booster heater, the booster heater tank must first be filled with water.
TO FILL BOOSTER HEATER WITH WATER:
4. Press and hold the manual fill switch on the right side of the control box until you hear water being sprayed from the rinse
arms, indicating that the rinse tank is filled with water.
TO ENABLE THE BOOSTER HEATER:
5. Connect the orange/white wire in the control box from the heater contactor to the orange/white wire on terminal board 2.
NOTE: Ensure the orange/white wires at the heater contactor are connected properly. They have been purposely
disconnected at the factory to avoid damage to the heater element when there is no water in the booster tank.
6. Run a few machine cycles to verify the correct operation of the machine.
Check for water leaks.
Verify that the rinse temperature is between 180°F and 195°F for the entire rinse sequence. If it is not, before adjusting the rinse
thermostat, verify that the incoming water temperature is 110°F minimum and that the incoming water flow pressure is 20
A
5 psi
(measured during the rinse sequence). Adjust the pressure regulating valve as necessary to achieve 20
A
5 psi.
TO FILL WASH TUB:
To Fill Wash Tub depress the “On -Off” switch to the “On” position. Depress and hold Fill Switch until you
see water draining out from the bottom of the machine. Open door for 3 seconds and close, this will start machine cycle. Allow
machine to complete one cycle, and then check for proper water level.
Note:
Water must be in the sump while the machine is running to avoid running the pump dry and causing damage to the pump
seal.
If the water level is not at the level noted above it will require adjustment. Check to ensure that the recommended water pres-
ES-2000HT INTL Installation & Operation Manual 7610-003-24-90
Issued: 07-10-2006 Revised: N/A
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
OPERATING INSTRUCTIONS
8
Summary of Contents for ES-2000HT INTL
Page 2: ......
Page 6: ...1 SECTION 1 SPECIFICATION INFORMATION...
Page 10: ...5 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS...
Page 17: ...12 SECTION 3 PREVENTATIVE MAINTENANCE...
Page 19: ...14 SECTION 4 TROUBLESHOOTING...
Page 23: ...18 SECTION 5 SERVICE PROCEDURES...
Page 30: ...25 SECTION 6 PARTS SECTION...
Page 51: ...46 SECTION 7 ELECTRICAL SCHEMATCS...
Page 55: ......