Ecojay SMartZone-2X Installation, Specification & Operation Download Page 7

I88

HI TEMP
LO TEMP

SUPPLY

PURGE

DELAY ECO

ecojay

SmartZone

FRESH AIR

I88

HI TEMP
LO TEMP

SUPPLY

PURGE

DELAY ECO

ecojay

SmartZone

FRESH AIR

1

1

72

2

2

78

3

3

67

4

4

84

ZONE

1 to 4

THERMO

-STATS

8

8

75

5

5

FAN

6

6

73

7

7

OFF

For systems with

 

5 to 8-Zones:

Connect two SmartZone-4X Controllers 

together using only a CAT 5 cable. 

(Wiring detail shown to right - 

same for 

primary and secondary controller

)

If two separate transformers are 
used for a SmartLINK application 
(using two 4X Boards to create 8 
zones), the primary and secondary 
polarity MUST be the SAME on both.

eco

jay 

llc.

1527 W State Highway 114
Suite 500-281
Grapevine, TX 76051
888-523-3265

ecojay.com

Work Smart… SmartZone

B
DUAL FUEL

ELECTRIC

 VLV. O

NORMAL

FAN GAS

LOCKOUT

2

nd

 STAGE

SMART LINK

ZONES (5 – 8)

ZONES (1–4)

S

M

A

R

T

 L

IN

K

1

GND

2

DIP SWITCH #6 should be set to 

“ZONES 

(5 

 8)

” on secondary 

SmartZone-4X ONLY

ZONE

5 to 8

SUPPLY 

DAMPERS

ZONE

5 to 8

THERMO

-STATS

BLUE SmartLINK LED 

“Flashing”

 indicates 

communication established 
and working.  

If LED is OFF 

or SOLID BLUE, check 
SmartLINK cable wiring or 
transformer polarity.

1

1

2

2

3

3

4

4

ZONE

1 to 4

SUPPLY 

DAMPERS

5

5

6

6

7

7

8

8

eco

jay 

SmartLINK

EASY

MAKES

8-ZONES

DO NOT CONNECT

EQUIPMENT OR SAS

TO SECONDARY “ZONES 

(5-8)

”  

SmartZone-4X CONTROLLER

SmartZone

4X

ONLY

with

AVAILABLE 

CONNECT 

EQUIPMENT

 AND SAS

TO PRIMARY “ZONES 

(1-4)

”  

SmartZone-4X CONTROLLER

*SEE CENTER 

PAGE FOR 

WIRING 

DETAILS

4X

SmartZone

ZS4X

2.0

4X

SmartZone

ZS4X

2.0

PRIMARY

 

(ZONE 1 to 4) 

SmartZone-4X

SECONDARY 

(ZONE 5 to 8) 

SmartZone-4X

12

Summary of Contents for SMartZone-2X

Page 1: ...AT SPARE FUSE INCLUDED FULL STATUS DIGITAL DISPLAY STATUS LEDs SHOW HEAT or COOL CALLS No Voltmeter Required EXCLUSIVE ECO FOR ENHANCED CONTROL QUICK SCREWLESS TERMINALS SmartZone 4X ZS4X 2 0 SCAN WITH SMARTPHONE FOR MORE INFO FRESH AIR CONTROL 4X ONLY STATUS LEDs SHOW DAMPER POSITION RED CLOSED GREEN OPEN USE ANY DAMPER 2 WIRE or 3 WIRE Power Open Close Spring Open or Spring Close SIMPLE SETUP AN...

Page 2: ...models Gas electric and or heat pump stats can be used on heat pump equipment heat pump stat is required on zone 1 only if emergency heat control is needed NOTE Use only gas electric stats with gas electric equipment DUCT DAMPERS PURGE TIME DELAY Time DELAY is designed for equipment protection After calls from all zones have been satisfied and the equipment is de energized a 3 minute Time DELAY wi...

Page 3: ... out can be adjusted up or down using the buttons See EQUIPMENT STAGING below for more details SET HIGH TEMP LIMIT CUT OUT SET LOW TEMP LIMIT CUT OUT IMPORTANT NOTE Changing either the LOW or HIGH temp limit will also affect the staging cut in and cut out temperatures settings Adjusting these can cause staging to occur sooner or later as needed See EQUIPMENT STAGING below for more details about ea...

Page 4: ...SUPPLY PLENUM ELECTRIC Auxiliary HEAT COIL RETURN AIR AIR FLOW Standard GE or All Electric Equipment Heat Pump Equipment Reversing valve energized in COOLING Reversing valve energized in HEATING Operates Aux Heat WITH compressor HP Only Operates Aux Heat WITHOUT compressor 2nd Stage Active Normal Operation 2nd Stage will not energize if only ONE zone open Energizes fan after 90 second delay in hea...

Page 5: ...ime cost and total number of dampers Connect dampers directly to the plenum with a starting collar and branch off smaller ducts going to different areas within the zones POWER DAMPERS Power Open Power Close dampers use three wires to power the damper open OR power it closed The zone panel is responsible for supplying a 24VAC signal to either the PO Power Open or PC Power Closed terminal of these d...

Page 6: ...on USE next size UP round bypass damper for any system with a single zone less than 200 CFM BYPASS DAMPER Pressure Relief A bypass system consists of a short duct connecting the supply plenum to the return air plenum A bypass damper is installed in this duct that opens closes automatically to maintain constant pressure inside the duct when zones open and close When the correct size bypass damper i...

Page 7: ...jay com Work Smart SmartZone B DUAL FUEL ELECTRIC VLV O NORMAL FAN GAS LOCKOUT 2nd STAGE SMART LINK ZONES 5 8 ZONES 1 4 SMART LINK 1 GND 2 DIP SWITCH 6 should be set to ZONES 5 8 on secondary SmartZone 4X ONLY ZONE 5 to 8 SUPPLY DAMPERS ZONE 5 to 8 THERMO STATS BLUE SmartLINK LED Flashing indicates communication established and working If LED is OFF or SOLID BLUE check SmartLINK cable wiring or tr...

Reviews: