Ecojay SMartZone-2X Installation, Specification & Operation Download Page 6

BYPASS Setup & Sizing

Static Pressure Controlled Bypass    (MODULATING)

TUBING INCLUDED

REMOVE CAP from 

LOW-PRESSURE INLET

Modulating Bypass

 

Configuration

The goal is to calibrate the bypass damper so that it is barely staying 

closed when all zones are open.  This will cause the bypass damper to 
open if supply dampers close and the plenum pressure increases.

WORKS WITH

3-WIRE

POWER CLOSE

POWER OPEN

ROUND OR 

RECTANGULAR

2

1

3

C

W2

O/B

W1

EH

Y1

Y2

G

E

Q

U

IP

M

E

N

T

ecojay

P

C

P

O

C

O

M

Static Pressure 

Controller (ASPC-2)

USE 18 Gauge Solid 

Core wire & Matching 

spade connectors 

(included)

NC

NO

COM

1

2

3

Wiring

Mounting

Mount with the sample line connections 

in the “

down

” position

. Use screws & 

standoffs through at least two of the four 

mounting feet holes. (As shown below)

 Air Probe (Pitot Tube)

Sm

ar

tZ

on

e

EQ

UI

PM

EN

T

DO NOT allow 

supply air 

pressure to blow 

directly into the 

pitot tube

PITOT

TUBE

To test if bypass is sized and 

configured properly, make a call ONLY 

from the smallest zone for cooling with 

the fan at the HIGHEST speed and the 

BYPASS Damper should fully or almost 

fully open within 1 to 2 minutes

Turn knob clockwise SLOWLY until the 

bypass damper motor starts closing

(ECOJAY damper RED light will flash)

If damper starts opening again before 

fully closing, turn the knob clockwise 

SLOWLY until it starts closing again.  

Repeat this process until the damper is 

fully closed.

(ECOJAY damper RED light will be solid)

VERY Slowly turn 

the knob counter-

clockwise until the 

bypass damper 

motor starts to run 

open.

(ECOJAY  damper 

GREEN light will 

flash)

Just as soon as the motor starts to 

run open, turn the knob back 

clockwise just enough that the 

damper motor stays closed.

(ECOJAY damper RED light will be 

solid)

ecojay

P

C

P

O

C

O

M

ecojay

P

C

P

O

C

O

M

ecojay

P

C

P

O

C

O

M

1

2

3

Connect the flexible tubing 

to the HIGH-PRESSURE 

INLET as shown

Pressure inlets 

pointing down

Make a call from ALL zones for cooling so all zone 

dampers are fully open AND the equipment fan 

(blower) is running at the HIGHEST speed.

4

AIRFLOW

Locate the air probe (pitot 

tube) at least

2 FEET

downstream from the air 

source, preferably as close 

to the center of the 

airstream as possible

High 

Pressure 

Inlet

Low 

Pressure 

Inlet

2 -2.5

10"

3 -3.5

12"

4 -4.5

14"

5

14 -16"

Unit Size 

Round Damper

(Tons)

Size (Inches)**

BYPASS DAMPER “RULE OF THUMB”

 

Below chart assumes 400 CFM per Ton 

**USE next size UP round bypass damper for any 

system with a single zone less than 200 CFM.

BYPASS DAMPER (Pressure Relief)

 

A bypass system 

consists of a short duct connecting the supply plenum to the return 

air plenum.  

A “bypass” damper is installed in this duct that opens

/

closes automatically to maintain constant pressure inside the duct 

when zones open and close.   When the correct size bypass damper 

is installed and adjusted correctly, it will be fully CLOSED when all 

zones are calling (no air bypassing) and will OPEN proportionately 

as more zone dampers close.

BYPASS DAMPER SIZING:

Select a round damper size with a Max CFM greater than the CFM-

Needed to bypass.  Use the formula below to calculate CFM needed 
to bypass and the ROUND DAMPER CFM CHART to check Max CFM.

T

YPICALLY

 400 

CFM

  

PER

  

TON

U

SE

 

“N

ORMAL

 

CFM” 

FROM

 

THE

 CFM CHART

(P

AGE

: 8)

U

SE

 

A

 BYPASS 

D

AMPER

 

THAT

 

HAS

 LARGER 

“M

AX

 

CFM”

800   = 2

1200 = 3

1600 = 4

2000 = 5

Bypass SIZE

E

QUIPMENT

 A

IRFLOW

C

APACITY

 

IN

 CFM (

HIGH

 

SPEED

)

CFM 

OF

S

MALLEST

 ZONE

CFM-N

EEDED

TO

 BYPASS

EXAMPLE: 4-T

ON

 

EQUIPMENT

 

WITH

  10" 

SMALLEST

 

ZONE

:

                  1600 CFM

(

EQUIPMENT

)

 

              

   400 CFM 

(

SMALLEST

 

ZONE

 

 N

ORMAL

 CFM 

ON

 P

AGE

: 8) 

      = 1200 CFM N

EEDED

               

     

SO, 

FROM

 

THE

 R

OUND

 D

AMPER

 MAX CFM 

ON

 P

AGE

: 8, 

A

 14" 

ROUND

 

DAMPER

 

SHOULD

 

BE

 

USED

 

FOR

 BYASS.

Mounting & Setup

It is critical that the Bypass Damper is adjusted properly for the Zoning system to work properly.

1. 

Remove the Weight arm from the damper at the shaft collar and move the weight to the end of head of the weight arm bolt.

2.

 Follow drawings to the right to install the damper and choose the proper

 initial weight arm position

 based on the

     direction of airflow.

3.

 Make a call for cooling from ALL zones & verify that all zone dampers are open.

4.

 Make sure the bypass damper remains closed.  If it is opening already, add more weight (ABDW).

5. 

Once the bypass damper is remaining closed, slowly move the weight toward the shaft (½ inch at a time) until the 

      bypass damper starts to open slightly.

6.

 Move the weight back about ½ inch so the bypass damper remains closed with all Zones open.

7.

 Close one or more zones by removing the cooling calls and ensure that the barometric bypass damper opens.

Barometric Bypass

Initial Weight-Arm Positions

 

depend on 

AIRFLOW            

and 

ORIENTATION

 of the bypass damper.  Below are the four (4)  

initial weight arm positions.  Select AIRFLOW & ORIENTATION for specific application.

NOTE: Extra weight may be required for 

upflow applications. (Order ABDW)

Up-Flow

o’clock Position

Left to Right

o’clock Position

Right to Left

o’clock Position

Down-Flow

o’clock Position

10

11

Summary of Contents for SMartZone-2X

Page 1: ...AT SPARE FUSE INCLUDED FULL STATUS DIGITAL DISPLAY STATUS LEDs SHOW HEAT or COOL CALLS No Voltmeter Required EXCLUSIVE ECO FOR ENHANCED CONTROL QUICK SCREWLESS TERMINALS SmartZone 4X ZS4X 2 0 SCAN WITH SMARTPHONE FOR MORE INFO FRESH AIR CONTROL 4X ONLY STATUS LEDs SHOW DAMPER POSITION RED CLOSED GREEN OPEN USE ANY DAMPER 2 WIRE or 3 WIRE Power Open Close Spring Open or Spring Close SIMPLE SETUP AN...

Page 2: ...models Gas electric and or heat pump stats can be used on heat pump equipment heat pump stat is required on zone 1 only if emergency heat control is needed NOTE Use only gas electric stats with gas electric equipment DUCT DAMPERS PURGE TIME DELAY Time DELAY is designed for equipment protection After calls from all zones have been satisfied and the equipment is de energized a 3 minute Time DELAY wi...

Page 3: ... out can be adjusted up or down using the buttons See EQUIPMENT STAGING below for more details SET HIGH TEMP LIMIT CUT OUT SET LOW TEMP LIMIT CUT OUT IMPORTANT NOTE Changing either the LOW or HIGH temp limit will also affect the staging cut in and cut out temperatures settings Adjusting these can cause staging to occur sooner or later as needed See EQUIPMENT STAGING below for more details about ea...

Page 4: ...SUPPLY PLENUM ELECTRIC Auxiliary HEAT COIL RETURN AIR AIR FLOW Standard GE or All Electric Equipment Heat Pump Equipment Reversing valve energized in COOLING Reversing valve energized in HEATING Operates Aux Heat WITH compressor HP Only Operates Aux Heat WITHOUT compressor 2nd Stage Active Normal Operation 2nd Stage will not energize if only ONE zone open Energizes fan after 90 second delay in hea...

Page 5: ...ime cost and total number of dampers Connect dampers directly to the plenum with a starting collar and branch off smaller ducts going to different areas within the zones POWER DAMPERS Power Open Power Close dampers use three wires to power the damper open OR power it closed The zone panel is responsible for supplying a 24VAC signal to either the PO Power Open or PC Power Closed terminal of these d...

Page 6: ...on USE next size UP round bypass damper for any system with a single zone less than 200 CFM BYPASS DAMPER Pressure Relief A bypass system consists of a short duct connecting the supply plenum to the return air plenum A bypass damper is installed in this duct that opens closes automatically to maintain constant pressure inside the duct when zones open and close When the correct size bypass damper i...

Page 7: ...jay com Work Smart SmartZone B DUAL FUEL ELECTRIC VLV O NORMAL FAN GAS LOCKOUT 2nd STAGE SMART LINK ZONES 5 8 ZONES 1 4 SMART LINK 1 GND 2 DIP SWITCH 6 should be set to ZONES 5 8 on secondary SmartZone 4X ONLY ZONE 5 to 8 SUPPLY DAMPERS ZONE 5 to 8 THERMO STATS BLUE SmartLINK LED Flashing indicates communication established and working If LED is OFF or SOLID BLUE check SmartLINK cable wiring or tr...