Ecojay SMartZone-2X Installation, Specification & Operation Download Page 2

DUAL FUEL 

FOSSIL FUEL AUX. HEAT

P

O

W
E

R

D

A

M

P

E

R

 1

24V

24C

Z1-PO

Z1-PC

ADJUST SETTINGS

RC

RH

COM

W2

O/B

Y1

Y2

G

E

Q

U

IP

M

E

N

T

REMOVE TO SEPARATE 
RC & RH TERMINALS

COM

Z

O

N

E

 1

 S

T

A

T

R

EC

Y

G

O/B

W

Z

O

N

E

 2

 S

T

A

T

R

C

Y

G

O/B

W

D

A

M

P

E

R

 2

Z2-PO

Z2-PC

COM

C

STAT

 TYPE

S

A

 S

E

N

S

O

R

SA1

SA2

W1

EH

I88

HI TEMP
LO TEMP

SUPPLY

PURGE

DELAY ECO

RESET

HEAT PUMP
B
DUAL FUEL

ELECTRIC

GAS/ELECT

RVS. VLV. O

NORMAL

FAN GAS

LOCKOUT

2

nd

 STAGE

ecojay

SmartZone

3

0

0

 m

A

2

Emergency Heat can ONLY be operated by a heat pump thermostat connected to the ZONE 1 

“W” thermostat terminal

.  SmartZone allows Gas/Electric or Heat Pump thermostats to be used 

on all zones with heat pump equipment.

If ZONE 1 thermostat calls for Emer. Heat, the SmartZone system will be LOCKED into 

emergency heat.  The compressor will NOT energize and only heating calls will be recognized 

from any zone other than ZONE 1.

Only W1/EH and G will be allowed to energize while SmartZone is LOCKED into emergency 

heat.  (ie. Compressor & cooling calls will be LOCKED OUT)

All cooling calls from ZONES 2 thru 4 will be ignored and any heating call from these zones 

will be treated by the SmartZone system as Emer. Heat.

To UNLOCK and take the system out of Emer. Heat, remove the Emer. Heat call at the ZONE 

1 thermostat 

AND

 make a call for compressor heat or cooling from this thermostat.

EMERGENCY HEAT

MORE INFORMATION AVAILABLE ONLINE 

- ecojay.com

ECONOMY MODE

ECONOMY  MODE  (ECO)  input  on  SmartZone  allows  the  use  of  a  switch, 

occupancy  sensor,  or  dry-contact  to  keep  Zones  2  thru  4  from  making 

equipment calls.  (i.e. Heat or Cool will not energize if only zones 2 thru 4 

are calling while EC Input is energized)  

Connect

  24V and EC INPUT to set 

the SmartZone System into ECONOMY MODE.  Only ZONE 1 will be able to 

make equipment calls.  All other zone calls will open and close dampers as 

needed  to  take  advantage  of  the  active  mode  energized  by  the  ZONE  1 

thermostat.  NO ADDITIONAL SETTINGS REQUIRED.

CLOSED

 = 

ECONOMY

SmartZone MODES & OPERATION

   1   SMARTZONE-4X (14 VA)

+ 4  POC  DAMPERS (3 VA X 4)

+ 4  THERMOSTATS (2 VA X 4)

= 37 VA

EXAMPLE

 

Transformer Calculation:

So, for this example of a basic 4-
Zone system, a 40VA transformer 
with a 2 AMP Fuse can be used.
SEE page 5 for more info about 
FUSE size.

24VAC TRANSFORMER (NOT INCLUDED) MUST BE 

SIZED AND FUSED BASED ON THE SMARTZONE 

CONTROLLER, TOTAL DAMPERS AND THERMOSTATS

POWER

14 VA

12VA

3 VA

10 VA

2 VA

ECOJAY Device

SmartZone-4X

SmartZone-2X

Power Open/Close Damper

Spring Return Damper 

Typical Thermostat

TRANSFORMER SIZING

24 VAC

 

TRANSFORMER

In  DUAL  FUEL  Mode,  the  compressor(s)  will  not  run  when  AUXILIARY  HEAT  is  energized.  

SmartZone  controls  dual  fuel  so  a  “dual  fuel  kit”  and  HEAT  PUMP  THERMOSTATS  are  NOT 

required.  GAS/ELECTRIC thermostats may be used with a heat pump system, however, use a 

Heat Pump stat for the ZONE 1 Thermostat to control EMERGENCY HEAT (Described above).  

Always  install  the  heat  pump  evaporator  downstream  of  the  furnace,  this  prevents 

condensation  in  the  heat  exchanger  during  the  cooling  mode.    SEE  SmartZone  Equipment 

Staging (p. 5) for more details about DUAL FUEL.

2X

ZS2X 

2.0

SmartZone

HVAC EQUIPMENT

PRE-INSTALLATION CHECKLIST

►Design all zones to balance the CFM 
evenly (each zone should be similar in 
size).

►Avoid creating small zones (< 20% of 
total capacity).

►Use proper excess (surplus) air-flow 
management including these techniques 

 bypass duct/damper, dump zone(s) or 
adjust dampers max close settings to allow 
leakage.  

►Ecojay recommends the use of a bypass 
duct/damper that is large enough to 
accommodate the total system CFM 
capacity minus the CFM capacity of the 
smallest zone.

►REFER TO pages 8,9,10,11 for more 
information.

►Perform basic equipment check including 
compressor, refrigerant charge, blower, 
furnace, filter before installing or starting 
up SmartZone system.

SMARTZONE PANEL

THERMOSTATS

►Calculate minimum 24V transformer VA capacity (add VA 
requirement for SmartZone cont # of therm # & 
type of dampers) 

– see Transformer Sizing section this page.

►Check primary and secondary voltage for zoning 
transformer.  Make sure separate transformer and circuit is 
use from equipment transformer.

►Select mounting location that provides space and easy path 
to run wires.

►Select location that provides easiest path to run wires.

►Do not mount where exposed directly to air stream from 
supply air grills.

►Do not mount where exposed to radiant heat from windows 
or skylights.

►Do not use power stealing or triac models.

►Gas/electric and/or heat pump stats can be used on heat 
pump equipment (heat pump stat is required on zone 1 only if 
emergency heat control is needed). 
NOTE: Use only gas/electric stats with gas/electric 
equipment.

DUCT & DAMPERS

PURGE

TIME DELAY

 

Time DELAY is designed for equipment protection.  After calls 

from all zones have been satisfied and the equipment is de-

energized, a 3-minute Time DELAY

 

will be completed before 

new thermostat calls will be processed.  During the DELAY all 

dampers  open  and  the  equipment  will  NOT  run.    During 

DELAY  the  digital  display  will  count  down  the  number  of 

seconds  left  during  purge  time  if  a  new  call  is  energized. 

NOTE: 

Although  SmartZone  will  not  energize  the  fan  (or 

equipment)  during  DELAY  the  equipment  being  used  may 

have  a  built  in  control  that  causes  the  fan  to  continue 

running.

RC/RH JUMPER

The  RC/RH  Jumper  is  Factory  Installed  on  the  SmartZone 

Controller.  If the equipment requires separate transformers 

for  heat  and  cool,  REMOVE  the  RC/RH  jumper  [JP2]  below 

the EQUIPMENT connector on the right side.

NOTE: 

In the case of a Heat-Pump System,

the RC/RH jumper should NOT be removed.

COMM 

– 

3 Wire Communications to SmartLINK (BLUE) [Use Cat5 Cable ONLY]

10K Type III Thermistor

SA Sensor 

– 4" Supply Air Temperature Sensor Stainless Steel Probe 

(Provided with each SmartZone)

P

O

W

E

R

O

U

T

P

U

T

S

IN

P

U

T

S

EQUIPMENT

DAMPERS

PROTECTION

SYSTEM

SmartZone-2X
SmartZone-4X

THERMOSTAT

TEMPERATURE

14VA MAX (375 mA @ 24VAC) [2X = 12VA, 8X = 28VA]

If multiple transformers are used in 8X system, the primary and secondary polarities must 
be the same for both transformers and on both ZS4X boards.

14VA + Stats (2VA ea.) + Dampers (3- 10 VA ea.)= Total Transformer Size

Integrated 

5X20mm 300mA Fuse

- One replacement also included. 

(

Field supplied transformer should also be fused

)

10 AMP @ 24VAC Contact Rating
RH

 

– 24VAC 

HOT

 from Heating Transformer on Equipment (RED)

RC

 

– 24VAC 

HOT

 from Cooling Transformer on Equipment (RED)

C

 

– 24VAC COMMON from Transformer on Equipment (none)

Y1

 

– 1

st

 Stage Compressor (YELLOW)

Y2

 

– 2

nd

 Stage Compressor (YELLOW)

G

 

– Fan (GREEN)

W1/EH

 

– 1

st

 Stage Heat OR Emergency Heat (RED)

W2/OB

 

– 2

nd

 Stage Heat OR Reversing Valve (ORANGE)

10 AMP @ 24VAC Contact Rating (40VA)

Power-Close / Spring-Open Dampers (10VA)
Power-Open / Spring-Close Dampers (10VA)
Power-Open / Power-Close Dampers (3VA)

LABEL

 

– DESCRIPTION (LED COLOR)

– 24VAC 

HOT 

(RED)

– Common (NONE)

– Compressor (YELLOW)

– Fan (GREEN)

– Heat OR Emergency Heat (RED)

O/B

 

– Reversing Valve (ORANGE)

EC 

– Economy Input (GREEN) 

ß

 Zone ONE only

SmartLINK (COMM)

SPECIFICATIONS

3

DISPLAY OPERATION & FUNCTION

Supply Air Temperature displayed. 

“--“ 

on temp display = SAS disconnected.

System is in PURGE mode for equipment 
changeover (Fan [G] and dampers continue to 
operate, Countdown timer on digits          sec.)

HIGH TEMP LIMIT sensed, SmartZone 
Controller de-energizes equipment HEAT output 
for a minimum of 3 minutes (Fan [G] and damper 
outputs continues to operate) 

Setting HIGH TEMP LIMIT 

– Press UP or DOWN 

Arrow Buttons to adjust the HIGH TEMP LIMIT 
(factory default:  heat pump 

– 120

o

 F; electric 

heat 

– 135

o

 F;  gas heat 

– 135

o

 F)

SUPPLY

PURGE

HI TEMP

(ON)

HI TEMP

(FLASHING)

LO TEMP

(ON)

LO TEMP

(FLASHING)

DELAY

ECO

(ON)

LOW TEMP LIMIT sensed, SmartZone Controller 
de-energizes equipment COOL output for a 
minimum of 3 minutes (Fan [G] and damper 
outputs continue to operate) 

Setting LOW TEMP LIMIT 

– Press the UP or 

DOWN Arrow Buttons to adjust the LOW TEMP 
LIMIT (factory default 48

F)

SmartZone Controller has satisfied all calls and will 
DELAY 3 min before initiating any additional calls.
(Countdown timer on digits           sec. if call made)

EC input on Zone 1 is energized and system is in 
ECONOMY MODE.  Only Zone 1 can initiate 
equipment calls, other zones will only open and 
close dampers as needed.

If ZONE 4 has been configured for FRESH AIR 
and FRESH AIR is being currently satisfied.  FAN 
should be running and ZONE 4 (FA Damper) 
energized in the OPEN position

ECO

(FLASHING)

I88

Multi-function digits show supply temperature, 
cut-out temperatures (high and low), zone 
thermostat types, fresh-air time.

A 3 minute PURGE of the supply air plenum is initiated during 

Opposing-Call  Changeover.  (Switching  from  Heat  to  Cool  or 

Cool  to  Heat)  During  the  PURGE,  the  fan  will  remain 

energized  to  purge  existing  supply  air  temperature  and  to 

allow equalization of hvac system pressures before energizing 

the  opposing  mode  call.  During  the  PURGE  Mode,  zone(s) 

calling for the opposite mode will have damper(s) closed. All 

other  dampers  (non-calling  zone(s)  and  zone(s)  calling  for 

mode  last  energized)  will  remain  open  during  PURGE  Mode.

During PURGE the digital display will count down the number 

of seconds left during purge time.

I80

I80

Summary of Contents for SMartZone-2X

Page 1: ...AT SPARE FUSE INCLUDED FULL STATUS DIGITAL DISPLAY STATUS LEDs SHOW HEAT or COOL CALLS No Voltmeter Required EXCLUSIVE ECO FOR ENHANCED CONTROL QUICK SCREWLESS TERMINALS SmartZone 4X ZS4X 2 0 SCAN WITH SMARTPHONE FOR MORE INFO FRESH AIR CONTROL 4X ONLY STATUS LEDs SHOW DAMPER POSITION RED CLOSED GREEN OPEN USE ANY DAMPER 2 WIRE or 3 WIRE Power Open Close Spring Open or Spring Close SIMPLE SETUP AN...

Page 2: ...models Gas electric and or heat pump stats can be used on heat pump equipment heat pump stat is required on zone 1 only if emergency heat control is needed NOTE Use only gas electric stats with gas electric equipment DUCT DAMPERS PURGE TIME DELAY Time DELAY is designed for equipment protection After calls from all zones have been satisfied and the equipment is de energized a 3 minute Time DELAY wi...

Page 3: ... out can be adjusted up or down using the buttons See EQUIPMENT STAGING below for more details SET HIGH TEMP LIMIT CUT OUT SET LOW TEMP LIMIT CUT OUT IMPORTANT NOTE Changing either the LOW or HIGH temp limit will also affect the staging cut in and cut out temperatures settings Adjusting these can cause staging to occur sooner or later as needed See EQUIPMENT STAGING below for more details about ea...

Page 4: ...SUPPLY PLENUM ELECTRIC Auxiliary HEAT COIL RETURN AIR AIR FLOW Standard GE or All Electric Equipment Heat Pump Equipment Reversing valve energized in COOLING Reversing valve energized in HEATING Operates Aux Heat WITH compressor HP Only Operates Aux Heat WITHOUT compressor 2nd Stage Active Normal Operation 2nd Stage will not energize if only ONE zone open Energizes fan after 90 second delay in hea...

Page 5: ...ime cost and total number of dampers Connect dampers directly to the plenum with a starting collar and branch off smaller ducts going to different areas within the zones POWER DAMPERS Power Open Power Close dampers use three wires to power the damper open OR power it closed The zone panel is responsible for supplying a 24VAC signal to either the PO Power Open or PC Power Closed terminal of these d...

Page 6: ...on USE next size UP round bypass damper for any system with a single zone less than 200 CFM BYPASS DAMPER Pressure Relief A bypass system consists of a short duct connecting the supply plenum to the return air plenum A bypass damper is installed in this duct that opens closes automatically to maintain constant pressure inside the duct when zones open and close When the correct size bypass damper i...

Page 7: ...jay com Work Smart SmartZone B DUAL FUEL ELECTRIC VLV O NORMAL FAN GAS LOCKOUT 2nd STAGE SMART LINK ZONES 5 8 ZONES 1 4 SMART LINK 1 GND 2 DIP SWITCH 6 should be set to ZONES 5 8 on secondary SmartZone 4X ONLY ZONE 5 to 8 SUPPLY DAMPERS ZONE 5 to 8 THERMO STATS BLUE SmartLINK LED Flashing indicates communication established and working If LED is OFF or SOLID BLUE check SmartLINK cable wiring or tr...