Installation Manual and Owner’s Guide WHO-321064-NG, WHO-321064-LP
ECOHOT
TM
13 of 27
THE FOLLOWING OPERATIONS SHOULD ONLY BE PERFORMED
BY A LICENSED
TECHNICIAN
.
Venting System
: Should be checked annually. Clean as needed. Before removing cover appliance
should be unplugged, Water and gas valve should be shut off.
Main Burner Flames
: The main burner flames should be blue. Yellow flames could be a sign of
wrong size gas orifices or dirty burners, or a blockage on the heat exchangers fins. If some burners
have yellow flames while others have blue flames, it is likely that dust, lint or spider webs have
partially clogged the burner ventures. To clean the burners, contact a gas service person.
Cleaning
: The water heater should be cleaned annually, keep the dust away from flue gas
passageway. See the Cleaning Instructions below.
DANGER
: Hot
water heater temperature over 125°F can cause severe burns instantly
or death from scalding. Children, the disabled and the elderly are at the highest risk of being
scalded. Feel water temperature before bathing or showering.
WARNING: Read and follow water heater warnings and instructions. If owner’s
manual is missing or damaged contact the retailer or go to “Greenworksunlimited.com” for a
copy.