Loosen screw from test point and connect manometer tube on test point.
2. Maximum Manifold Pressure adjustment
◆
Plug in Power cord.
◆
Turn on all hot water taps served by the water heater.
◆
Adjust the temperature setting up to 140 F (60 C), make sure water heater’s all burners
working.
◆
Adjust Dip Switch 1 and Switch 2 to ON position, let water heater work on full capacity
conditions, on the condition of Inlet Gas Pressure is 11 inches W.C. (2740Pa) for LPG and
7 inches W.C. (1740Pa) for Nature Gas. Refer Fig:Switches.
◆
Use a small crossing screw driver adjust The Adjustable Resistance of PCB which marked
“MAX”, to meet the data of De-rating Manifold Max. Pressure from the De-rating
Manifold Pressure Table.