11
– The charge size is in accordance with the room size within which the
refrigerant containing parts are installed;
– The ventilation machinery and outlets are operating adequately and
are not obstructed;
– If an indirect refrigerating circuit is being used, the secondary circuit
shall be checked for the presence of refrigerant;
– Marking to the equipment continues to be visible and legible.
Markings and signs that are illegible shall be corrected;
– Refrigeration pipe or components are installed in a position where
they are unlikely to be exposed to any substance which may corrode
refrigerant containing components, unless the components are
constructed of materials which are inherently resistant to being
corroded or are suitably protected against being corroded.
2.2.9 Checks to Electrical Devices
Repair and maintenance to electrical components shall include initial
safety checks and component inspection procedures. If a fault exists
that could compromise safety, then no electrical supply shall be
connected to the circuit until it is satisfactorily dealt with. If the fault
cannot be corrected immediately but it is necessary to continue
operation, an adequate temporary solution shall be used. This shall be
reported to the owner of the equipment, so all parties are advised.
Initial safety checks shall include:
-the capacitors are discharged: this shall be done in a safe manner to
avoid possibility of sparking;
-that there no live electrical components and wiring are exposed while
charging, recovering or purging the system;
-that there is continuity of earth bonding.
Summary of Contents for ecoQ CoolAir 10
Page 2: ......
Page 21: ...19 5 OPERATION 5 1 CONTROL PANEL AND DISPLAY 5 2 REMOTE CONTROL ...
Page 51: ...49 5 FONCTIONNEMENT 5 1 PANNEAU DE COMMANDE ET AFFICHAGE 5 2 TELECOMMANDE ...
Page 80: ...78 5 BETRIEB 5 1 BEDIENFELD UND DISPLAY 5 2 FERNBEDIENUNG ...
Page 111: ...109 5 FUNZIONAMENTO 5 1 PANNELLO DI CONTROLLO E DISPLAY 5 2 TELECOMANDO ...
Page 124: ......