1.
VAP100 TECHNICAL FEATURES.
CONNECTIONS
Heating return - Male thread.
“ / DN
2 / DN50
Heat flow – Male thread.
“ / DN
2 / DN50
Charge – Discharge – thread female
“ / DN
3/4 / DN20
Safety valve discharge – thread female
“ / DN
3/4 / DN20
Gas output
mm
200
External silo connection.
mm
50
AIR ADMISSION
Maximum air flow admission (Estimation according to mass flow and gas
temperature in nominal power).
m
3
/h
Regulation
Minimum draught recommended
mBar Pa
Regulation
HYDRAULIC
Expansion vessel
L
Maximum working pressure.
Bar / KPa
2,5 / 250
Minimum working pressure.
Bar / KPa
0,5 / 50
Recommended working pressure.
Bar / KPa
1,2 / 120
Calibrated safety valves.
Bar / KPa
3,0 / 300
Water volume inside boiler
L
365
Head loss on water side
dt=10 K
mBar
418
dt=20 K
mBar
315
GENERAL FEATURES
Weight
kg
1360
Auxiliary Hopper (Fuel estimate ρ
ap
≈630 kg/m
3
)
kg
50
Hopper volume.
L
Weight of the turbulator cylinder, Stage 1
kg/ud
1,7
Weight of the turbulator cylinder, Stage 2
kg/ud
2,3
Weight of the cyl positioner set. (14+14)
Kg
4
Weight of the helix turbulator Stage 1
kg/ud
Weight of the helix turbulator Stage 2
kg/ud
Weight of the helical c positioner set
kg/ud
Volume of the ash box
L
45
Airborne noise according to the UNE EN 15036-1
dB
65
SILO CONDITIONS.
Maximum hose length *.
m
5
Maximum height allowed.
m
4
Minimum curve radius.
m
1
Each curve is equivalent to 1m, so if we have 2 curves the maximum length would be 5m.