Holiday calendar
Used to schedule up to 3 periods a year when the heat pumps stay on or off.
5.2.3.
HEATING Menu
Heating
This enables the HEATING mode and adjusts the heating cut-off temperature. The
HEATING mode is never activated for temperatures over the cut-off setpoint.
External BOILER
This is used to enable the auxiliary boiler in both EMERGENCY and SUPPORT mode.
In EMERGENCY mode, the auxiliary system is activated automatically when any of the
alarms are active.
In SUPPORT mode, the auxiliary system is activated automatically for normal HEAT
production, as programmed by the technical service.
5.2.4.
COOLING Menu
Cooling
This is used to enable the COOLING mode and adjust the active and passive cooling cut-
off temperatures. The COOLING mode cannot be activated for outside temperatures
under the cooling cut-off temperature. Only PASSIVE COOLING can be activated for
outside temperatures between passive and active cut-off temperatures. ACTIVE
COOLING activation is only allowed for outside temperatures over the active cooling cut-
off temperature.
Auxiliary chiller
This is used to enable the auxiliary chiller in both EMERGENCY and SUPPORT mode.
In EMERGENCY mode, the auxiliary system is activated automatically when any of the
alarms are active.
In SUPPORT mode, the auxiliary system is activated automatically for normal COOLING
production, as programmed by the technical service.
Holiday schedule
Enable:
State:
Swiched Off
Sp Season
Start Stop
Month/Day / /
Month/Day / /
3Month/Day / /
4:5
User menu
/8
On/Off
Schedule
Heating
3/8
Heating
Enable:
StopT:
External boiler
Emergency:
Support:
User menu
4/8
Heating
ooling
DHW/Legionella prot
4/8
ooling
Enable:
StopT:
Active:
8
Passive:
External chiller
Emergency:
Support:
8