background image

pag.37

LB972  

MULTICALOR 300.1-400.1 PR/AB     

AB

ESPIA DE BL

OQUEO RELE TERMIC

O

LAMPE 

DE 

THERMA

L DE 

SECURITE

THERMA

L L

OCK-OUT LAMP

LAMP

ADA 

DI 

BL

OC

CO

 TERMIC

O

EX

TRA 

SAFET

GAS 

SOLENOID 

VA

LV

E

LO

CK

-O

UT

 LA

M

P

ESPIA GAS

LAMPE 

DE 

GAZ

GAS 

LAMP

ESPIA 

DE 

BL

OQUEO

LAMPE 

DE 

SECURITE

RELE'

RELAIS

RELA

Y

ESPIA GASOLEO

TEMOIN MAZ

OUT

OIL 

LAMP

TELERRUPT

OR 

MO

TO

VENTILA

TOR

CO

NT

AC

TEUR 

MO

TEUR 

VENTILA

TEUR

REMO

TE 

CO

NTROL 

SWIT

CH 

(FAN 

MO

TO

R)

EMP

ALME MO

TO

R BOMBA

CO

NT

AC

TEUR 

MO

TEUR 

POMPE

POMP 

REMO

TE 

CO

NTROL 

SWIT

CH

CO

NT

AT

TO

RE

 M

OTO

RE

 V

EN

TI

LA

TO

RE

CO

NT

AT

TO

RE

 M

OTO

RE

 P

OM

PA

RELE'

LAMP

ADA 

GASOLIO

LAMP

ADA 

GAS

KMV

KMP

KA

2

HLg

HL

G

ELECTROV

AL

VULA 

DE 

GASOLEO 

DE 

SEGURIDAD

ELECTROV

ANNE MAZ

OUT DE SECURITE

EX

TRA 

SAFET

OIL 

SOLENOI

VA

LV

E

ELET

TROV

AL

VOLA GASOLIO DI SICUREZZA

ELECTROV

AL

VULA 

GAS 

PIL

OT

O

ELECTROV

ANNE 

GAZ 

PIL

OTE

PIL

OT 

FLAME 

SOLENOID 

GAS 

VA

LV

E

ELET

TROV

AL

VOLA GAS PIL

OT

A

ELECTROV

AL

VULA GAS DE SEGURIDAD

ELECTROV

ANNE 

GAZ 

DE 

SECURITE

PRESOST

AT

GAS 

DE 

MINIMA 

PO

T.

PRESSOST

AT

 GAZ PRESSION MIN

GAS 

PRESSURE 

SWIT

CH 

MIN

PRESSOST

AT

O GAS DI MINIMA

YV

gS

SPGmin

YV

GP

INTERRUPT

OR 

GENERAL 

CO

FUSIBLE

INTERRUPTEUR GENERAL A

VEC FUSIBLE

MAIN SWIT

CH WITH FUSE

FIL

TRO 

DE 

PRO

TECION 

 ANTIDISTURBI

O

FIL

TRE 

ANTIP

AR

ASITES

ANTJAMMING 

FIL

TER

RELE'

RELAIS

RELA

Y

FUSIBLE

FUSIBLE

FUSE

MO

TO

VENTILADOR

MUTEUR 

VENTILA

TEUR

MO

TOR 

FAN

MO

TOR 

BOMBA

MO

TEUR 

POMPE

OIL 

PUMP 

MO

TOR

TR

ANSFORMADOR

TR

ANSFORMA

TEUR 

D'ALL

UMA

GE

IGNITION 

TRANSFORMER

FO

TOCEL

ULA

CELL

ULE 

 UV

UV CELL

RELE' 

TERMIC

MO

TO

VENTILADOR

RELAIS 

THERMI

QUE 

MO

TEUR 

VENTILA

TEUR

MO

TO

THERMA

L RELA

(FAN 

MO

TO

R)

RELE' 

TERMIC

MO

TO

BOMBA

RELAIS 

THERMI

QUE 

MO

TEUR 

POMPE

MO

TO

PUMP 

THERMAL 

RELA

Y

LAMP

ADA 

DI 

BL

OC

CO

RELE' 

TERMIC

MO

TO

RE 

VENTILA

TORE

RELE' TERMIC

O MO

TO

RE POMP

A

FO

TOCELL

ULA

TRASFORMA

TORE

MO

TO

RE VENTILA

TORE

MO

TO

RE POMP

A

RELE'

FUSIBILE

FIL

TRO ANTIDISTU

RBO

INTERRUT

TO

RE GENERALE C

ON FUSIBILE

UV

HLB

FMV

FMP

TV

MV

MP

KA

FU

Z

Q

SWIT

CH (OIL-GAS)

CO

M

M

UT

AT

OR

E G

AS

OL

IO

-G

AS

INTERRUPTEUR 

MAZ

OUT-GAS

CO

NM

UT

AD

OR

 G

AS

OL

EO

-G

AS

THERMO

ST

AT

 GRANDE-PETIRE 

ALL

URE

HIGH-L

OW 

FLAME 

THERMOS

TA

T

TERMOST

AT

DI 

AL

TA

-BASSA 

FIAMMA

CO

MMUT

AT

ORE 

MANU

ALE-A

UT

OMA

TIC

O

SWIT

CH (MANU

AL-A

UT

OMA

TIC))

INTERRUPTEUR MANUEL-A

UT

OMA

TIQUE

CO

NMUT

ADOR 

MANU

AL-A

UT

OMA

TIC

O

ELECTROV

AL

VULA DE GASOLEO 1^ LLAMA

ELECTROV

ANNE MAZ

OUT PETITE ALL

URE

FIRST 

ST

AG

E OIL 

SOLENOI

VA

LV

E

ELET

TROV

AL

VOLA 

GASOLIO 

DI 

PRIMA 

FIAMMA

ELECTROV

AL

VULA 

GAS 

DE 

1^ 

LLAMA

ELECTROV

ANNE 

GAZ 

PETITE 

ALL

URE

FIRST 

ST

AG

E GAS 

SOLENOID 

VA

LV

E

ELET

TROV

AL

VOLA 

GAS 

DI 

PRIMA 

FIAMMA

ELET

TROV

AL

VOLA GAS DI SICUREZZA

TERMOST

AT

DE 

AL

TA

-BAJA 

LLAMA

YV

G

YV

GS

YV

g

ST

AB

SA

gG

SAMA

INTERRUT

TO

RE DI LINEA

WORKING SWIT

CH

PRESSOST

AT

O ARIA

AIR 

PRESSURE 

SWIT

CH

PRESSOST

AT 

AIR

PRESOST

AT

AIRE

INTERRUPTEUR DE LIGNE

INTERRUPT

OR 

DE 

LINEA

SAFET

Y THERMOST

AT

TERMOST

AT

CALDAIA

BOILER 

THERMOS

TA

T

THERMO

ST

AT CHA

UDIERE

TERMOST

AT

CALDER

A

TERMOST

AT

DI 

SICUREZZA

TERMOST

AT

DE 

SEGURIDAD

THERMO

ST

AT DE SECURITE

ST

S

ST

C

SP

A

SAL

HLB

T

PA

GI

NA

 D

I

IN

D.

M

O

DI

FI

CA

SO

ST

.D

A

SO

ST

.IL

IN

D.

M

O

D.

PROPRIETA' RISER

VAT

A DELLA DIT

TA EC

OFLAM S.p.A.

DA

TA

-F

IR

M

A

DAT

A

FIR

MA

CO

NT

RO

LL

AT

O

DE

SC

RI

ZI

O

NE

 M

O

DI

FI

CA

DI

SE

GN

AT

O

DAT

A

FIR

MA

COM

UNI

CAR

E A

 TE

RZI

 IL 

CON

TEN

UTO

 DE

L P

RES

ENT

E.

A TE

RM

INE

 DI L

EGG

E E'

 VIE

TAT

O R

IPR

ODU

RRE

 O

CO

NT

RO

LL

O

 D

I T

EN

UT

A

APP

AREC

CHIA

TURA

UFF

.TECNIC

O-SET

TORE ELET

TRIC

O

DENOMINAZI

ONE

SIST

. RIVELAZ.

CO

DICE

MO

TO

RIDUT

TO

RE

S.p

.A.

00

01

02

03

04

05

06

07

08

09

A

00

01

02

03

04

05

06

07

08

09

B

C

D

E

A

B

C

D

E

BEM43178

MUL

TICAL

OR 300.1 - 400.1 - 500.1 PR/PR

LANDIS 

SQM50.481A2

LANDIS LFL 1.333

VPS 504

UV

22

-0

6-

20

05

CAMMA 

REGOLAZION

E ARIA 

BASSA 

FIAMMA

 GASOLIO

CAMMA 

DI 

REGO

LAZIONE 

ARIA 

AL

TA

 FIAMMA 

(GAS-G

ASOLIO)

CAMMA 

REGOLAZION

E ARIA 

MINIMA 

PO

TENZA 

GA

SOLI

CAMMA 

DI 

REGO

LAZIONE 

ARIA 

BA

SSA 

FIAMMA 

GAS

CAMMA 

DI 

REGO

LAZIONE 

ARIA 

MINI

MA 

PO

TENZA 

GAS

CAMMA 

NON 

UTILIZZA

TA

CAMMA 

NON 

UTILIZZA

TA

 V

: VI:

 VIII:

 VII:

 I:

 II:

 III:  IV

:

16

IV

0

00

I

II

III

0

0

VI

I

V

VI

VI

II

LANDIS 

SQM 

50.481A2

1

12

11

N

21

1

22

2

13

M

24

14

23

3

4

15

25

5

7

26

6

17

27

2/

2

CAMMA 

DI 

CHIUSUR

TO

TA

LE

Summary of Contents for Multicalor 300.1 PR

Page 1: ...LB1448 20 07 2005 Multicalor 300 1 PR MD Multicalor 400 1 PR MD Light oil Natural gas 40 300 mbar Light oil LPG 75 300 mbar MODELS A BRUCIATORI MISTI GAS GASOLIO B GAS LIGHT OIL DUAL BURNERS...

Page 2: ...atural Gas L C V 8 570 kcal Nm3 LPG L C V 22 260 kcal Nm3 Light oil L C V 10 200 kcal kg max visc 1 5 E at 20 C OVERALL DIMENSIONS Burner output Backpressure in combustion chamber I M L E D D1 F C B A...

Page 3: ...the air servocontrol in approximately 30 seconds time When the servocontrol is fully open a signal to the electronic control unit starts the 66 seconds pre purge cycle At the end of the prepurging tim...

Page 4: ...ation probe which cuts in and sets the burner shutdown within the safety time In case of gas lack or a major pressure drop the minimum air pressure switch shuts down the burner Ref Description t1 Dura...

Page 5: ...STING THE MAXIMUM CAPACITY OF THE GAS Position the selector situated on the control panel on position 1 and proceed as follows Adjusting the maximum gas flow rate see figure on solenoid valve adjustme...

Page 6: ...p cover M ADJUSTMENT OF THE AIR PRESSURE SWITCH Unscrew screws A and B and remove cover C Set the pressure switch to the mini mum by turning regulator D to position 1 Start the burner and keep in low...

Page 7: ...st be suitable for burner The connection of boiler s thermostats and all the safeties The motor rotation direction The correct calibration of the motor s thermal protection When all the above mentione...

Page 8: ...button on the control box If after a successful pump priming the burner locks out after the prepurging due to a fuel pressure drop in the pump rearm the burner s lock out to restart the burner Do neve...

Page 9: ...p 5 Selector 0 Loking of devoices for operating at intermediate outputs Operation at max output Operation at min output AUTO Automatic operation 6 Main switch I O 7 Selector 0 Light oil Gas 8 Lockout...

Page 10: ...ses are blown out The control box is faulty THE BURNER RUNS THE PREPURGING AND SWITCHES TO LOCKOUT AT THE END OF CYCLE Check the fan and the air pressure Check the air pressure switch Control box faul...

Page 11: ...LOSE 1st Stage Increase power OPEN 2nd Stage Two stage operation Description of display and keys on the RWF 40 microprocessor regulator The figure shows the normal display indicating the actual value...

Page 12: ...to access the parameters level To move from one parameter to the next press PGM PGM When HYS1 is displayed burner ignition differential stage II increase or decrease the value using the and keys Conf...

Page 13: ...1 Connection for probe QAE2 passive probe Water probe Configuration code C111 9XXX Connection for probe FT TP passive probe Degusa probe Configuration code C111 5XXX Connection for probe QBE620 P act...

Page 14: ...faulty the regulator will not indicate the real value Situation The number 1999 blinks in the display as the actual value with SP E showing in the set point field Cause The external set point value i...

Page 15: ...e relative opening in the electrical panel A Insert the fixing anchors and screws into the slots and secure the unit to the panel B To open the regulator squeeze the cover from the ends as shown and l...

Page 16: ...ive probe QBE620 P QAE22 FT TP 1000 P4 P10 P16 P25 P40 Analog input 1 2 and 3 setpoint changeover shift C111 9030 5030 G000 G000 G000 G000 G000 Limit comparator controller type setpoint 1 locking C112...

Page 17: ...A UV 19 03 1998 Q N BEM43167 3 MULTICALOR 300 1 400 1 500 1 PR PR LANDIS SQM 50 481A2 LANDIS LFL 1 622 VPS 504 UV 11 03 2005 FMP 95 96 KMV R S T NO FMV MV U V W FMP MP U V W S R T KMP R S T NO SAMA 1...

Page 18: ...TV MV MP KA FU Z Q SWITCH OIL GAS COMMUTATORE GASOLIO GAS INTERRUPTEUR MAZOUT GAS CONMUTADOR GASOLEO GAS THERMOSTAT GRANDE PETIRE ALLURE HIGH LOW FLAME THERMOSTAT TERMOSTATO DI ALTA BASSA FIAMMA COMM...

Page 19: ...2005 FMP 95 96 KMP R S T NO KMV R S T NO MP U V W MV U V W Q HLB FMV FMP S R 10 11 8 5 6 7 9 T N FMV 95 96 SAgG 1 2 3 0 SAMA 1 2 3 0 FMV 97 98 HLBT GAS 2 GASOLIO 1 COMMUTATORE ALTA BASSA FIAMMA SWITC...

Page 20: ...LIO GAS INTERRUPTEUR MAZOUT GAS CONMUTADOR GASOLEO GAS TERMOSTATO DE SEGURIDAD COMMUTATORE MANUALE AUTOMATICO SWITCH MANUAL AUTOMATIC INTERRUPTEUR MANUEL AUTOMATIQUE CONMUTADOR MANUAL AUTOMATICO THERM...

Page 21: ...1 33 LFL 1 622 VPS 504 UV 22 06 2005 FMP 95 96 KMV R S T NO FMV MV U V W FMP MP U V W S R T KMP R S T NO SAMA 1 2 3 0 HLBT FMV 97 98 SAgG 1 2 3 0 GAS 2 GASOLIO 1 T P STC 50 Hz 400V HLB STAB T P STS R...

Page 22: ...MP KA FU Z Q SWITCH OIL GAS COMMUTATORE GASOLIO GAS INTERRUPTEUR MAZOUT GAS CONMUTADOR GASOLEO GAS THERMOSTAT GRANDE PETIRE ALLURE HIGH LOW FLAME THERMOSTAT TERMOSTATO DI ALTA BASSA FIAMMA COMMUTATOR...

Page 23: ...6 Q N BEM43188 1 MULTICALOR 300 1 400 1 500 1 PR PR LANDIS SQM 50 481A2 LANDIS LFL 1 333 LFL 1 622 PREDISPOSTO UV 03 11 2005 FMP 95 96 KMV R S T NO FMV MV U V W FMP MP U V W S R T KMP R S T NO SAMA 1...

Page 24: ...TATORE GASOLIO GAS INTERRUPTEUR MAZOUT GAS CONMUTADOR GASOLEO GAS THERMOSTAT GRANDE PETIRE ALLURE HIGH LOW FLAME THERMOSTAT TERMOSTATO DI ALTA BASSA FIAMMA COMMUTATORE MANUALE AUTOMATICO SWITCH MANUAL...

Page 25: ...400 1 PR AB Multicalor 300 1 PR MD Multicalor 400 1 PR MD 7 8 36 11 14 4 6 5 3 9 10 39 26 31 29 30 27 34 32 33 52 35 28 2 37 20 13 12 25 24 22 23 19 21 17 16 15 18 1 41 50 51 44 43 47 53 38 49 42 46 4...

Page 26: ...802 2 24 REL BASE Finder 5532 R905 R905 Finder 5534 R906 R906 25 REL Finder 5532 R711 R711 Finder 5534 R712 R712 26 UV CELL LANDIS QRA 2 A205 A205 27 IGNITION CABLE TC BFE01403 2 BFE01403 2 TL BFE0140...

Page 27: ...right to make without any prior notice all those modifications which it deems usefull and or necessary in order to improve the quality of its products without affecting their main features CEcoflam S...