pag.22

techniques for energy saving

LB1360   

MULTICALOR 700.1÷1200.1 MD 

TC = SHORT HEAD   TL = LONG HEAD

Multicalor 1000.1 MD

DESCRIPTION

code

1 - AIR PRESSURE SWITCH

DG 10 U

Q112/2

2 - AIR INTAKE SET 

GRPA100

3 - WIELAND PLUG

6 pin

E226

4 - COVER

BFC09255/038

5 -  GLASS

BFC02004

6 - PEED WINDOM FRAME

BFC02006

7 -  MOTOR

22 kW

M170/61

8 - FAN

RG-630

BFV10401/001

9 - AIR CONVEYOR

BFC08260

10 - CONVEYOR RING

BFC08258/038

11 - AIR INTAKE

GRCA630

12 - CONTROL BOX BASE

LANDIS

A401

13 - CONTROL BOX

LANDIS LFL1.622

A113

14 - IGNITION TRANSFORMER 

BRAHMA T8

T101

15 - REMOTE CONTROL SWITCH

AEG LS15K.00

R621/5

16 - REMOTE CONTROL SWITCH (PUMP)

AEG LS11K.00

R621/4

17 - MOTOR THERMAL RELAY

AEG B18K-320

R521/16

18 - MOTOR THERMAL RELAY (PUMP)

AEG

R521/5

19 - MAIN SWITCH

cod.40100I1509

R1020

20 - RESET BUTTON

C5559AL

R1021

21 - SELECTOR

R1020/5

22 - LAMP

Elettrospring EL/N-SC4

E1510

23 - FUSE SUPPORT

FUSIT FH-B528

E802/2

24 - RELÉ BASE

Finder 5532

R905

Finder 5534

R906

25 - RELÉ

Finder 5532

R711

Finder 5534

R712

26 - TIMER

AEG SDE

R527

27 - UV CELL

LANDIS QRA 2

A205

28 - IGNITION CABLE

TC

BFE01403/3

29 - IGNITION ELECTRODES SET

E612/1

30 - PIPE

TC

31 - ROD

TC

32 - GAS FIRING HEAD
33 - FRONT DISC
34 - OIL FIRING HEAD
35 - COIL

EL011

V523

36 - CONNECTOR WITH RECTIFIER

V1119/07

37 - INNER ASSEMBLY

TC

38 - BLAST TUBE 

TC

BFB07022/103

39 -  GASKET  ISOMART

BFG04059/1

40 - ANTIJAMMING FILTER

S132/4

41 - AIR DAMPER MOTOR

LANDIS SQM50.481A2

M212/91

42 - SILENCER

BAA11001

43 - OIL PUMP

SUNTEC T5C105

P1481/04

44 - COUPLING

MP501/4

45 - PUMP MOTOR

4 kW ABB

M147/91

46 - OIL  VALVE

LUCIFER 121

V1751

47 - COIL

LUCIFER 3541

V522

48 - OIL  VALVE

PARKER PM133IV

V175/9

49 - COIL

PARKER ZB 14

V516/1

50 - OIL FILTER

70501/03

S107/5

51 - HOSES

TN 18X1500

S902

52 - MANOMETER

CEWAL R1/4 D50-40BAR

S601/1

53 - PILOT GAS VALVE

DUNGS SV-DLE 507

V1994/21

54 - COIL

DUNGS

55  -   OIL VALVE

SUNTEC TV40011

P1481

56 - NOZZLE

BERGONZO kg/h 650

57 - MODULATING UNIT

LANDIS RWF 40

E1215

Summary of Contents for Multicalor 1000.1 MD

Page 1: ...S T E C LB1360 27 05 2004 Multicalor 700 1 MD Multicalor 800 1 MD Multicalor 1000 1 MD Multicalor 1200 1 MD Light oil Natural Gas 300 mbar MODELS techniques for energy saving GAS LIGHT OIL DUAL BURNE...

Page 2: ...500 2 000 2 500 2 700 kcal h 1 290 000 1 724 000 2 155 000 2 327 600 Max capacity Natural Gas Nm3 h 729 855 1 056 1 318 Min capacity Natural Gas Nm3 h 150 201 251 272 Max light oil flow rate kg h 613...

Page 3: ...carried out with the max air delivery the burner control circuit turns the air damper to the max delivery position by the air servocontrol in approximately 30 seconds time When the servocontrol is fu...

Page 4: ...rging the ignition tran sformer cuts in and generates a spark between the electrodes At the same time the two gas valves open Vs safety valve and Vl working valve The total safety in case of missed ig...

Page 5: ...m gas flow rate see figure on solenoid valve adjustments or adjust the gas pressure in the governor ADJUSTING THE MAXIMUM AIR FLOW RATE Adjusting the maximum air flow rate see figure detail 2 Loosen t...

Page 6: ...essure switch to the minimum by turning regulator D to position 1 Start the burner and keep in low flame running while checking that combustion is cor rect Through a small cardboard progressively obst...

Page 7: ...e motor s thermal protection When all the above mentioned conditions are checked and accomplished it is possible to go on with burner s tests Power the burner The control box feeds the ignition transf...

Page 8: ...ation That check valve is suitably designed for the duty The pump pressure is set at a value of 22 25 bar during the testing of burners Before starting the burner bleed the air in the pump through the...

Page 9: ...pag 9 LB1360 MULTICALOR 700 1 1200 1 MD techniques for energy saving...

Page 10: ...pag 10 techniques for energy saving LB1360 MULTICALOR 700 1 1200 1 MD...

Page 11: ...ation Before going on with the maintenance controls of the burner it should be advisable to check its general conditions according to the following steps Unplug the burner close the fuel cock shut dow...

Page 12: ...s are clogged Light oil pressure is too low Combustion air s flow rate too high related to nozzle output THE BURNER RUNS THE PREPURGING BUT DOES NOT IGNITE Check the position of the electrodes check t...

Page 13: ...educe power CLOSE 1st Stage Increase power OPEN 2nd Stage Two stage operation Description of display and keys on the RWF 40 microprocessor regulator The figure shows the normal display indicating the...

Page 14: ...e PGM PGM key to access the parameters level To move from one parameter to the next press PGM PGM When HYS1 is displayed burner ignition differential stage II increase or decrease the value using the...

Page 15: ...31 4 Cod S720 1 Connection for probe QAE2 passive probe Water probe Configuration code C111 9XXX Connection for probe FT TP passive probe Degusa probe Configuration code C111 5XXX Connection for probe...

Page 16: ...the probe is faulty the regulator will not indicate the real value Situation The number 1999 blinks in the display as the actual value with SP E showing in the set point field Cause The external set...

Page 17: ...or through the relative opening in the electrical panel A Insert the fixing anchors and screws into the slots and secure the unit to the panel B To open the regulator squeeze the cover from the ends a...

Page 18: ...ive probe active probe QBE620 P QAE22 FT TP 1000 P4 P10 P16 P25 P40 Analog input 1 2 and 3 setpoint changeover shift C111 9030 5030 G000 G000 G000 G000 G000 Limit comparator controller type setpoint 1...

Page 19: ...SA BEM43141 MULTICALOR 1000 1 MD LANDIS SQM 50 481A2 LANDIS LFL 1 622 DUNGS VDK 200 A UV 06 05 2004 FMP 95 96 KMP R S T NO Q HLB S1 R1 10 11 8 5 6 7 9 T1 N FMV 95 96 SAgG 1 2 3 0 SAMA 1 2 3 0 FMV 97...

Page 20: ...FETY THERMOSTAT SWITCH OIL GAS SAgG STS PRESSOSTAT AIR PRESOSTATO AIRE TERMOSTATO CALDAIA BOILER THERMOSTAT STC INTERRUPTOR GENERAL CON FUSIBLE INTERRUPTEUR GENERAL AVEC FUSIBLE MAIN SWITCH WITH FUSE...

Page 21: ...000 1 MD 4 8 9 39 28 29 33 37 38 57 3 1 5 42 31 30 32 2 6 10 11 53 54 0 15 30 45 60 75 90 0 I 0 AUTO 0 OIL GAS OIL GAS RESET 21 19 20 FIN D FIN D FIN DER FIN DER 13 7 12 15 16 17 18 K6 RWF 40 PGM PGM...