 INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

TC42
CHALET
BURNER KIT
INSTRUCTIONS

PART#

TC42.NG01.C
For TC  42
Series C

These instructions are supplementary to the Installation and 
Operating Instructions supplied with the fi replace and should be 
kept together. Refer to the Installation and Operating Instructions 
for proper gas supply, safety requirements and operating 
instructions

Summary of Contents for TC42

Page 1: ...42 CHALET BURNER KIT INSTRUCTIONS PART TC42 NG01 C For TC 42 Series C These instructions are supplementary to the Installation and Operating Instructions supplied with the fireplace and should be kept...

Page 2: ...Contents of Package 2 TC42 NG01 C 281009 12 BURNER ASSEMBLY LOG GRATE TC42 LOGS EMBER MATERIAL HARDWARE PACKAGE...

Page 3: ...and tighten Fig 3 Ensure there are no leaks 4 Attach spark electrode ORANGE and sensor leads to the electrical bulk head Fig 4 Thesparkelectrodeconnection has a red dot above it A panel set must now...

Page 4: ...for best performance Fill the burner pan level with the top of the pan at rear and gradually sloping forward down to the firebox floor at the front covering both burner tubes Place remaining ember mat...

Page 5: ...the following pictures Place the rear log back against the tabs located at the back of the grate Place left log as pictured engaging the pins with corresponding holes on the underside of the log Inst...

Page 6: ...or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete un til the operation of the converted appliance is check...

Page 7: ...shows NG position Fig 18 shows LP position 10 Remove access panel to access control assembly Fig 18a 10 Removetheminimumratescrewlocated in the valve Fig 19 Fig 18 Fig 19 Fig 16 Fig 17 7 TC42 NG01 C...

Page 8: ...op of the pressure regulator Fig 21 13 Press down on the center post and rotate 90 The center post should stay down Fig 22 Replace the rubber cap 14 Fill in the date and the name of the personwhoperfo...

Page 9: ...replace the plug Thread sealant will be required to ensure a gas tight connection Correct gas pressure requirement Supply Pressure Natural Gas Propane For purpose of input adjustment Minimum 5 0 WC 1...

Page 10: ...The shutter may also be opened to enhance the Ember Material glow and lessen the flame height Caution Burner area may be hot Turn off the fireplace and allow the unit to cool before proceeding Caution...

Page 11: ...BURNER ASSEMBLY 1a GRATE 1b BURNER TRAY 1c BURNER TRAY SUPPORT SHIELD 1d BURNER TRAY SHIELD GASKET 1e MANIFOLD 1f 1 2 PIPE TO 1 2 TUBE CONNECTION 1g PILOT BRACKET 2 7 PCS LOG SET 2a LOG 1 2b LOG 2 2c...

Page 12: ...TECHNICAL SUPPORT 1 888 715 2664 www townandcountryfireplaces net 2975 Allenby Rd Duncan BC V9L 6V8 Printed in Canada...