9
according to temperature of indoor pipe coil to make the best of surplus energy of indoor
pipe coil.
2.5.8 Temperature control for compressor vent
Vent temperature sensor detects the temperature of refrigerant air exhausted from
compressor and control rotary speed of compressor
(
same as cooling and heating
)
to ensure
high efficient operation of system.
2.5.9 Sleep control
(
soft operation
)
Press“sleep” button on remote controller
,
the unit will control rotary speed of compressor
and indoor fan motor and enters sleep operation:
Rotary speed of fan motor
:
medium level or lower lever
Rotary speed of compressor
:
decrease
The set temperature will decrease 1
℃
automatically after running for 1 hour; After running
for another 1 hour, the set temperature will go on decreasing 1
℃
. But the set temperature
displayed on LED will remain unchanged.
2.5.10 Outdoor fan motor control
(
except defrosting
)
The speed of outdoor motor is decided in low or higher according to the outdoor
surroundings temperature and the indoor pipe temperature.
2.5.11 compressor frequency control
A Frequency range of compressor is 25-100Hz
。
B Original frequency of compressor
:
Set by original indoor temperature and surroundings
temperature.
C Running frequency of compressor is controlled by artificial intelligence.
2.6 “Smart”function
The unit will judge the operation mode automatically after receiving the SMART signal.
2.6.1 Original set temperature
:
Choosing indoor temperature according to set temperature.
2.6.2 Original mode
:
Choosing original mode according to outdoor temperature and
indoor temperature. There are three modes are available: cooling, heating, fan sweep
Fan sweep mode
:
High level
,
louver blades swing automatically and can be adjustable.
In“Smart”mode, all additional function is available. Indoor fan speed is set as automatic and
louver swing automatically. Outdoor rotary speed is controlled according to the
corresponding mode, and users can adjust position of louver and temperature.
Unit will judge next working mode after finishing operation of a kind of mode. If in fan sweep
mode, unit will enter mode to judge program every per minute until enter cooling or heating
mode.
2.6.3 Judge mode again
:
Choosing cooling(heating/fan sweep) mode according to indoor,
outdoor temperature and the set temperature.