ETS 64-R
0548-990-61---70g_2019.10.indd
–
+
dAxis
Default
6
4
3 s
5 s
0,2 s
OFF
0,5 s
2,0 A
OFF
OFF
4
4
0
0
95°
*
STD-PH
*
OFF
*
0/+8 cm
Rod dep.
*
5 A
5 A
Vo
Vc
TOEx
TKey
TDelay
FDelay
TLock
FLock
FSlam
FWind
Fo
Fc
Foh
Fch
Ao
Rod
Invers
dAxis
Fos
FTic
0..14 (5…50°/s)
0..14 (5…50°/s)
0...60 s
0...180 s
0,0...4,0 s
0,0...7,0 A
0,0...4,0 s
0,0...7,0 A
0...10
OFF
OPEN
CLOSE
BOTH
0...9
0...9
0...9
0,0...3,5 A
20...(190°) Rod dep.
STD-PH
SLI-PL
SLI-PH
WIN-PH
DIR-PH
DIR-PL
OFF
ON
-8...+25 cm
Rod depending
5...14 A
5...14 A
0548-990/62g
Page 65 of 95
Mounting and operating instructions
Mounting plate
7.4.1
Motional parameters (PARAMETER)
Parameter Description
Opening speed (velocity open)
Closing speed (velocity close)
Hold-open time opening element inside/outside (time hold opening element inside/outside)
Hold-open time Key (time hold opening element Key)
Starting delay (time delay lock)
Relieving force during unlocking (force delay), only effective if TDelay is > 0
Door rectification time (time press close)
Pressing force during locking (force lock), only effective if TLock is > 0
Accelerating function (force slam)
Obstacle detection optimized for exterior doors (force wind)
Opening force (force open)
Closing force (force close)
Hold-open force (force open hold)
Interlocking force (force close hold)
automatically programs FLock and FDelay if these are 0
Opening angle of the door (angle open)
If the opening angle is changed during the operating mode OPEN, the operating mode MANUAL needs to be
selected for closing the door.
Type of rod assembly (Rod)
Normal rods
pushing fonction
Sliding rods
pulling fonction
Sliding rods
pushing fonction
Wing mounting
pushing fonction
without rods
pushing fonction
without rods
pulling fonction
Inverse application
In the event of a power failure/error, the door leaf is opened by spring power from any position (unless it has
not been locked). The position of the motor connector is reversed with regard to the standard drive mecha
-
nism. The electric lock/holding magnet must be connected in reverse order in comparison to the standard
drive mechanism (see wiring diagram E4-0141-713_ECO).
Distance between rotation axis of the door hinges and the mounting level of the drive mechanism
(distance Axis). dAxis is an approximate value. Depending on the installation situation, dAxis may have to be
adapted.
Limitation of the opening force
Must not be increased in Germany!
Closing force in closed position before Teach (only visible if Inverse is ON).
Setting range
* Note:
A renewed setting-up procedure
(Teach) is required.