-Setup the battery bank

The inverter in this system requires a 24V battery bank for running.

With 2 pieces of batteries, the connection should be:

Connect 2 batteries in series to form a 24V battery bank. Method: hook 

up each battery’s positive terminal to the other’s negative terminal.

The diagram as below:

-Connect solar charge controller with battery

The solar charge controller should be put indoor. After the battery bank 

setup accomplished, wire the controller with battery bank. The controller 

has 3 parts of ports, middle ports are for connecting with battery.

Wiring method: Use the controller-battery cable for connection, battery 

+ port to one battery’s positive terminal, battery - port to the other’s neg-

ative terminal

Summary of Contents for ECO-SC60A

Page 1: ...Tel E mail customer service eco worthy com Web www eco worthy com 44 20 7570 0328 EU 1 866 939 8222 US ...

Page 2: ...Contents 1 Safety Caution 2 Product Overview 3 Components Description 4 Installation Guide 5 Fusing and Setting 6 Testing and Troubleshooting 7 FAQ 8 Maintenance 9 Support 1 1 3 7 14 15 17 18 19 ...

Page 3: ...between the solar panel charge controller and the battery Reverse polarity may causedamage Make sure all wire connections are tight and secure loose connections may cause sparks and intermittent behavior Do not perform installation in the presence of any flammable materials Make sure you work in a well ventilated area Use properly insulated tools adjustable wrench wire stripper screw driver wire c...

Page 4: ... PCs 12V 50AH Lithium Battery 1 Pair of 16ft 11AWG Solar Controller Cable 1 Pair of Y Branch Connector 1 Pair of 1ft 10AWG Lithium Battery Cable 1 Pair of 2 6ft 7AWG Battery Inverter Cable 1 Pair of 16 4ft 12AWG Solar Extension Cable 1 Pair of 4 92ft 11AWG Battery Controller Cable 4 Sets of Z Bracket Necessary bolts and nuts designed for plane installation 2 ...

Page 5: ...ttery bank make the charging process safe and effctive Electrical Data Maximum Power at STC Optimum Operating Voltage Vmp Optimum Operating Current Imp Open Circuit Voltage Voc Short Circuit Voltage Isc Module Efficiency Weight Size 100W 18V 5 55A 21 6V 6 11A 19 41 13 14 lbs 5 96 kg 1010 510 35mm 39 8 x 20 1 x1 4 in Solar Cable Connectors Rated Current Maximum Voltage Maximum AWG Size Range Temper...

Page 6: ...rge Power Frequency Effienvy Working Temperature Size 24V DC 110V AC 1500W 3000W 60Hz 90 10 50 13 8 5 9 3 14 inch Battery plate reverse connection protec tion a battery reverse connection protec tion charging battery board short circuit protection charging the battery open circuit protection charging over current protection overload protection load short circuit protection controller and over temp...

Page 7: ...wer Battery Voltage Maximum Charge Discharge Current Charge Temperature Range Disharge Temperature Range Maximum Charge Voltage Discharge Cut Off Voltage Battery Weight Battery Size 50Ah 640Wh 12 8V 40A 60A 32 F 131 F 0 C 55 C 4 F 131 F 20 C 55 C 14 5V 10V M6 4 9kg 10 8lb 8 8 5 3 7inch 22 13 5 17 8cm 16 4ft Extension Cable 16 4ft 12AWG MC4 copper head cable for solar panel array controller connect...

Page 8: ...onnection Battery Controller Cable 4 92ft 11AWG cable for battery controller connection Z Mounting Brackets Mounting brackets for fixing panel to a flat surface There are 4 brackets for each solar panel Y Branch Connecotr Split Y shape cable for parallel connection of solar panels ...

Page 9: ...al to the other s negative terminal The diagram as below Connect solar charge controller with battery The solar charge controller should be put indoor After the battery bank setup accomplished wire the controller with battery bank The controller has 3 parts of ports middle ports are for connecting with battery Wiring method Use the controller battery cable for connection battery port to one batter...

Page 10: ... and the combiner box For Northern Hemisphere installations the solar panels should be mounted at an angle facing true south true north for Southern Hemi sphere installations The mounting angle should be equal to the latitude location of where you are installing the solar panels For exam ple the latitude of Miami Florida USA is 25 degrees Therefore solar panels installed in this area should ideall...

Page 11: ...s Using a well nut is recommended as the rubber expansion prevents water leak age The Z Bracket set does not include well nuts Step1 Attaching the Z Bracket to a solar panel Locate the mounting holes on the solar panel Solar Panels have four mounting holes on each side Step2 Mark and drill holes With the Z Brackets attached to the frame the panel can be laid on a mounting surface making it easier ...

Page 12: ... washer hold the well nut in place when the screw is fastened Gently insert the well nut into the drill hole Be careful not to push the well nut flange completely into the holes Make sure the flange is flushed on the roofline Before attaching the panel to the roof a film of caulk can be laid between the RV roof and the Z Bracket Even though the well nut provides a watertight bond this provides add...

Page 13: ...ls in series to make 2 strings of 24V Each ECO WORTHY Solar Panel has a pair of MC4 solar cable at the back of panel that consists of male and female connectors This type of connector uses a snap in type of safety locking clips to lock the two mating connectors making it easy to install For series connections just plug one panel s male and the other s female MC4 connectors together ...

Page 14: ...inals to plug the Y branch connector terminals and the copper head terminals to the controller PV input port for positive cable for negative one Place the inverter The inverter should be put indoor to avoid raindrop or any other weather issue that may causes electrical fault Here some notice should be followed 2 Use 1 pair of Y branch connector to wire 2 strings together in parallel Diagram as bel...

Page 15: ...se do not install the inverter in a humid greasy flam mable explo sive dusty or other severe environments During cabinet installation sufficient space shall be reserved around the hybrid inverter for heat dissipation The polarity of the battery input end of this product shall not be reversed otherwise the device may be damaged easily or there may be some unpredictable dangers It can be mounted on ...

Page 16: ...and is defined by the following Two Strings in Parallel fusing not required So no need to fuse the PV array you built or the connection between it and controller LCD display screen info battery present voltage Note the inverter only works when 24V battery bank connected Inverter to appliances Before booting the inverter the AC OUT ports should be wired with the home socket or appliances first Turn...

Page 17: ...nt Test modules connected in series before they are connected to the system To determine Voc and Isc in the following tests the module s must be exposed to the sun and not connected to a load Observe personal safety when making these measurements Check the open circuit voltage Voc of every series module using a digital multimeter The measured system Voc should correspond to the sum of the Vocs of ...

Page 18: ...ing or remove the diode the issue may be sorted Removing the bypass diodes should only be done by a compe tent PV technician and the module has to be disconnected from the system In the case of fine irradiance if the voltage across the terminals differs from the rated value by more than 15 this indicates a bad electrical connection 16 Determine the short circuit current Isc of every series circuit...

Page 19: ...fy battery voltage is sufficient to power up the inverter A2 Everything is hooked up correctly The sun is shining directly onto the solar panels but no charge is going to the batteries Q2 Check the voltage of the battery bank The battery bank is most likely fully charged and the solar charge controller inside the hybrid inverter has disconnected the solar panels from the battery The solar charge c...

Page 20: ...t can be used to remove dirt Check the electrical and mechanical connections every six months to verify that they are clean secure and undamaged Inspect the solar panels and make sure the surfaces are free from dust dirt and other debris clean with a wet cloth or glass cleaner if neces sary Check to make sure all structural components mechanical fasteners and electrical connections are secure clea...

Page 21: ... or patent rights The information in this manual is based on ECO WORTHY s knowledge and experience and is believed to be reliable but such information including product specification without limitations and suggestions do not constitute a warranty expresses or implied ECO WORTHY reserves the right to change the manual the PV prod ucts the specifications or product information sheets without prior ...