13
Step D - Install Storage Tank
The fitting on the supply tank may need to be tightened
7-8 full turns to get a good seal.
Do not overtighten.
INSTALL STORAGE TANK
1. Apply of thread sealing tape (2 wraps clockwise) to
the threads on the nipple at the top of the tank. See
Fig 14.
2. Locate the tubing connector. See Fig. 14. Tighten the
tubing connector onto the tank nipple 7-8 full turns,
being careful not to cross thread or overtighten.
3. Do not connect the tube at this time. This will occur
later in the assembly.
4. Place the storage tank next to the Reverse Osmosis
Assembly. The tank can be placed upright or on its
side.
FIG. 14
Tank
Nipple
Storage
Tank
Tubing Nut
Tubing Insert
Tubing Connector