9
Step A - Install Supply Water Fitting
Cold Water Supply Fitting
(Included in package)
Use to Connect
Tubing
1/4” green tubing
to Reverse
Osmosis inlet
water supply fitting
(tee feed adaptor)
cold
water
faucet stud
cold
water
pipe
Check and comply with local plumbing codes as you plan,
then install a cold feed (supply) water fitting. Refer to the
Specifications page for supply water requirements. The fit-
ting must provide a leak-tight connection to the RO 1/4" tub-
ing. A typical connection using the included water supply fit-
ting is shown in Figure 7.
NOTE: Local code may dictate which type of water fit-
ting is used. Consult a plumber if you are not familiar
with local codes or plumbing procedures.
NOTE: Codes in the state of Massachusetts require
installation by a licensed plumber and do not permit
the use of saddle valves.
If you live in the state of Massachusetts, review plumb-
ing code 248-CMR of the Commonwealth of
Massachusetts before proceeding with the installation.
INSTALL COLD WATER SUPPLY FITTING
(Included with your package)
This fitting will be installed on the cold water pipe. The fit-
ting must provide a leak-tight connection to the Reverse
Osmosis 1/4" tubing. Locate the cold water line in the sink
cabinet. It is recommended, but not required, that the cold
water line be soft water..
Complete the following steps to install the water supply fit-
ting:
1
. Close the house main water shutoff valve and open
faucets to drain water from the sink cold water pipe.
2
. Remove nut that connects the cold water faucet to cold
water plumbing.
3
. Use pipe joint compound or Teflon tape on the cold water
faucet stud threads and on the male threads of the water
supply fitting that connect to the cold water pipe.
FIG. 7
Cold Water
Shutoff Valve
Hot Water
Shutoff Valve