1.
PUMPABLE LIQUIDS
-
Max. particle size Ø.20 inch.
The pump is watertight and must be immersed in liquid.
2.
TECHNICAL SPECIFICATIONS
• Supply voltage: 115 – 120V, see electrical data plate
• Delayed line fuses (115 – 120V version): indicative values (Ampere)
• Storage temperature: 14º F – 104º F
Fresh water
●
Rainwater
●
Clear waste water
●
Dirty water
❍
Waste water containing solid particles with long fibers
❍
Fountain water
●
River or lake water
●
●
Suitable
❍
Not suitable
Hydraulic
data
Dimensions/weight
Range of use/materials
Max. pressure
Max. head
Max. working pressure
Low suction capability
(MAN)
8.1 psi
|
0.6 Bar
18 ft
|
5.5 m
87 psi
|
6 Bar
0.08-0.12 in
|
2-3 mm
TECHNICAL SPECIFICATIONS
Electrical
data
Power
Voltage
Frequency
Amps
Flow rate max.
240 Watt
115 V-120 V AC
60Hz
2
25.5 gpm
|
5800 l/h
Dimension of particles
Pump dimensions
See illustration
Liquid range temperature
Max. ambient temperature
DNA / DNM NPT
Net weight
0.2 in
|
5 mm
8.1 in x 5.9 in x 9.7 in
205 mm x 150 mm x 245 mm
Length of power cable
32.8 ft
|
10 m
32°-95° F
|
0°-35° C
104° F
|
40° C
1¼ in M
/
1¼ in F
Impellers
1
8.25 lbs
|
3.75 kg