5.
Turn the room thermostat to “OFF”. The room air fan should stop after a period of
approximately 45 seconds.
6. Check the flue for leaks and spillage. Spillage may occur if the flue installation is faulty and is
not properly sealed. If so, this condition must be corrected.
The user must be instructed on how to correctly operate the system
All units are fitted with automatically resetting high temperature limit switches. It is important to
leave a minimum number of registers open otherwise the unit will cut out on the high temperature
limit.
Minimum number of Vents openings
-
The following minimum number or more vents should always remain open-
SS512- 2
SS516 and HB416- 3
SS520 and HB420- 4
SS525- 5
SS530- 6
In case of less than above number of vents are open, or there is a power failure, the unit may
overheat and short-cycle, or go to lockout mode and the high temperature manual overheat limit
switch may activate and may require human intervention to reset. When more vents are opened
and or power is restored the overheat auto-reset high temperature limit will automatically reset
but the thermostat may have to be turned down and up again to re-set and re-start the system.
Abnormal Operation
Should any of the following characteristics occur, advise the user to contact their local Eco Pacific
service agent or the local gas authority immediately:
•
Smell of gas.
•
Unusual odours from supply air outlet registers/vents.
•
Smoke or fumes from supply air outlet registers.
•
Excessive or unusual noise emanating from the appliance.
Warnings
Advise the user of the following issues:
•
Do not place articles on or against the heater.
•
Do not use or store flammable materials near the heater.
•
Do not spray aerosols in the vicinity of the heater while it is in operation.
•
The front access panels of the heater must remain fitted while the unit is in operation.
•
Do not put filters in the supply air vents/registers.
Maintenance
Advise the owner/operator of the need to regularly clean any filters if fitted in the return air grill.
Never turn a dirty filter around to allow air to flow in the opposite direction. Cleaning or replacing