background image

JINECO05 revB 20/06/14 
 

Assembly 

Instructions 

Flue Collar and Blanking Plate 

Wind the eight M6 studs supplied into the fixing 
holes  in the  flue  collar  and  blanking  plate  until 
finger tight.   

 

Place a flue  gasket  in position on  the  top plate 
of  the  stove  and  lower  the  flue  collar  or 
blanking plate (as required) on to the stove top, 
taking  care  to  line  up  the  studs  with  the  fixing 
holes.   

 

Secure in place using the M6 nuts and washers. 
Slide  the  remaining  gasket  on  to  the  studs  of 
the  flue  collar  or  blanking  plate  and  secure  in 
place on the back plate. Unless the optional flue 
damper  is  being  fitted,  blank  off  the  damper 
handle holes in the flue collar using the two M8 
coach bolts. 

 

Removing  Internal 

Parts 

This set of instructions explains the removal 
sequence that you will need to employ when 
servicing your Hunter stove. 

1.

 

Open the stove door and remove the 
ash pan. 

2.

 

Remove the fuel retainer by lifting the 
right side up and sliding out from under 
the door catch cover (a) 
  

(a)

 

 

 

3.

 

Remove the baffle by pulling it forwards 
and sliding it to the left until the right 
side of it clears the baffle support and 
then lowering it into the firebox and 
removing it (b).

 

 

Summary of Contents for eco 5

Page 1: ...JINECO05 revB 20 06 14 eco 5 Clean Burn Stove Installation and Operating Instructions ...

Page 2: ...ve has been designed and assembled so that it may be used to burn wood logs in a Smoke Control Area Find out if you are in a Smoke Control Area by contacting your Local Authority The eco5 has been fitted with a permanent stop that prevents full closure of the secondary air control Any adjustment or modification to the stop will lead to the appliance potentially causing smoke emissions Without the ...

Page 3: ...legal requirement to notify your local building control body in advance of any work starting Health and Safety Precautions Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work Act are met Handling Adequate facilities must be available for loading unloading and site handling Fire Cement Some types of fire cement are caustic and should not ...

Page 4: ...ith the door open If fume emission does persist then the following action should be taken immediately Open doors and windows to ventilate room Let the fire out or eject and safely dispose of fuel from the appliance Check for flue chimney blockage and clean if required Do not attempt to relight the fire until the cause has been identified and corrected If necessary seek professional advice Adverse ...

Page 5: ...the flue collar or blanking plate and secure in place on the back plate Unless the optional flue damper is being fitted blank off the damper handle holes in the flue collar using the two M8 coach bolts Removing Internal Parts This set of instructions explains the removal sequence that you will need to employ when servicing your Hunter stove 1 Open the stove door and remove the ash pan 2 Remove the...

Page 6: ...y lifting them up and swinging the bottom towards the centre of the stove d d 6 Remove the rear bricks e e 7 Remove the cam bar by lifting the left hand end out of the side casting f and sliding the right right hand end from the hole in the side of the stove g taking care to retrieve the cam hole plate h f g ...

Page 7: ...d side casting by moving it upwards and out i i 9 Remove the rear grate support by lifting it upwards and out j This will allow you to remove the left hand side casting k j k 10 Remove the catch bar l l 11 Remove the base casting m m Cam Hole Plate ...

Page 8: ...ection to the Chimney The chimney must be swept before connection to the stove An existing fireplace opening can be bricked up or sealed with a register plate A short length of flue pipe of minimum 125mm internal diameter may then be used to connect the stove to the chimney This flue pipe should be made of 316 grade stainless steel or vitreous enamelled steel nominal thickness 1 2mm Ensure that th...

Page 9: ...mm thick this may include the thickness of a solid floor If the stove is not to stand in an appliance recess it may stand wholly above a hearth made of non combustible board sheet material or tiles at least 12mm thick The hearth should extend at least 150 mm from the sides and rear of the stove and at least 300 mm from the front of the stove All non combustible walls closer than 300mm to the stove...

Page 10: ...nly be operated as directed in the instructions It is essential that the stove has an adequate air supply for combustion and ventilation Primary Air Primary air is controlled via the slider at the bottom of the stove under the door The amount of air can be increased by moving the slider to the right This provides a conventional air draught to the bed of the fire Secondary Air Secondary air is cont...

Page 11: ...th the secondary air valve lever approximately 50 open and the primary control closed Moving the secondary control will adjust the burn rate of the stove Note primary and secondary air is needed to light the stove see section entitled Lighting the Stove Wood burns best on a bed of ash and it is therefore only necessary to remove surplus ash from the stove occasionally Refuelling must be carried ou...

Page 12: ...fire has been extinguished The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act 1993 local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed boiler if located in a designated smoke control area It is also an offence to acquire an unautho...

Page 13: ...eum coke fuels or household waste must not be burnt on this appliance This appliance should not be used as an incinerator No liquid fuels should be burnt on this appliance Should any difficulties arise over fuel quality or suitability consult your local approved coal merchant or HETAS Ltd Telephone 01242 673257 www hetas co uk Solid Fuel Association Telephone 0800 600 000 www solidfuel co uk GENER...

Page 14: ...nd at least twice a year for wood and other fuels The baffle will need to be removed from its supports in order to sweep the chimney see assembly instructions Only wire centred sweeps brushes fitted with a guide wheel should be used If it is not possible to sweep all parts of the chimney through the appliance ensure there is adequate access to cleaning doors Seasonal Use If the appliance has been ...

Page 15: ...m An extractor fan is not fitted in the same room as the stove Flue draught is above minimum level see installation instructions Fire blazing out of control Check that The doors are tightly closed The air controls are all in the closed position A suitable fuel is being used The glass retaining clips are not loose The door rope seals are in good condition Flue draught is below maximum level see ins...

Page 16: ...JINECO05 revB 20 06 14 Spares Information Door spares ...

Page 17: ...JINECO05 revB 20 06 14 Body Assembly Spares ...

Reviews: