STEP 1:

Disconnect the power to the primary sump pump so the only pump available is the Battery Backup Sump Pump.
STEP 2:

With a garden hose or buckets of water fill the sump basin with water. At the designated level of water, the Bat-

tery Backup Sump Pump should activate and the ALARM and ALARM INDICATOR LIGHT should come on. This 

indicates the system is working.
STEP 3:

Press the RESET button on the control/alarm panel and reconnect power to the primary sump pump. The test is 

complete.
NOTE: If the Battery Backup Sump Pump failed to activate, review the complete instructions.

The Battery Backup Sump Pump is designated as an emergency back up pump in the event your primary sump 

pump fails or if there is a loss of power to your primary sump pump.  

THE BATTERY BACKUP SUMP PUMP IS NOT INTENDED FOR USE AS A PRIMARY SUMP PUMP. 
PRIMARY SUMP PUMP FAILURE

In the event your primary sump pump fails or loses power, the Battery Backup System will automatically activate 

when the float switch reaches the ON position. When it turns on, a alarm will sound and the alarm indicator will 

light. When the water in the sump basin recedes and the pump turns off, the alarm will continue to sound until you 

depress the ON/OFF switch to the on/off switch to the ON position and press the RESET button.
BATTERY LOW 

In the event 12 volt battery charge should drop lower than 11 volts, the alarm will sound and the BATTERY LOW 

indicator will light. Press the ON/OFF switch to OFF position, disconnect power to the 12 volt transformer from the 

GFCI outlet and disconnect the pump and float switch cords from the alarm/control panel plugs. Have the bat-

tery checked, serviced or replaced if necessary. Once 12 volt battery is serviced or replaced, reconnect all plugs, 

cables and power and follow the Test Procedures listed in this owners manual.
BATTERY CHARGING/CHARGED 

When the battery is not at full charge capacity, the BATTERY CHARGING indicator will light. The battery charger 

is simply recharging the battery to its full charged capacity. Once the battery has reached full charging capacity 

(13 volts) the CHARGED indicator will light. 

If neither the BATTERY CHARGING or CHARGED indicator lights are on, check all wire connections and plugs to 

ensure proper hook up.
LEADS REVERSED 

If you connect the battery cable to the wrong battery terminal, the LEADS REVERSED indicator will light. Simply 

remove the battery cable and reconnect to the proper battery terminals. The RED WIRE is connected to the posi-

tive (+) terminal and the BLACK wire is connected to the negative (-) terminal. 

You must replace the 1 amp fuse with the extra fuse provided. Simply turn the fuse cover counter clockwise until 

the burnt fuse is exposed. Replace the fuse and thread the fuse cover, turning clockwise. 
BATTERY MAINTENANCE 

The 12 volt marine battery should be tested every four to six months. It is recommended to replace the battery 

every three to four years. Follow the battery manufacturers recommendations for proper battery maintenance and 

battery replacement. 

TESTING THE SYSTEM

NORMAL OPERATION

Summary of Contents for Water Ace WASBB

Page 1: ...Owner s Manual 12 Volt Battery Backup Sump Pump System General Safety 2 3 Contents Tools 4 Installation 4 6 Parts 5 Testing Operation 7 Warranty 8 TABLE OF CONTENTS...

Page 2: ...Call 1 844 394 2604 for assistance Do Not Return to Store Important Safety Instructions Carefully read and follow all safety instructions in this manual and on pump SAVE THESE INSTRUCTIONS This manua...

Page 3: ...utilate the battery Released electrolyte is harmful to the skin and eyes It may be toxic 3 The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes It is electrically conductive...

Page 4: ...ribed below to allow space for the supplied pump installation tee If discharge is 1 1 4 pipe cut off 1 1 2 of pipe If discharge is 1 1 2 pipe cut off 2 of pipe TOOLS Adjustable wrench or socket wrench...

Page 5: ...o the discharge pipe INSTALLATION Check Valve Backup Pump Suction Inlet Float Sensor Discharge Pipe 1 1 4 Tether 3 4 5 12 1 2 The top of the Battery Backup Pump should be at least 4 below the top of t...

Page 6: ...TIVE terminal and the BLACK WIRE to the NEGATIVE terminal STEP 4 Turn the alarm switch on the control alarm panel to the OFF position and plug the 12 volt transformer in a GFCI outlet If a GFCI outlet...

Page 7: ...ght Press the ON OFF switch to OFF position disconnect power to the 12 volt transformer from the GFCI outlet and disconnect the pump and float switch cords from the alarm control panel plugs Have the...

Page 8: ...tly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferable and does not apply to products used in commerc...

Reviews: