STEP 1:

Mount the Control/Alarm Panel to the battery case 

using the four mounting screws provided. Battery 

case has four mounting holes predrilled for easy 

installation of control panel. 
For best results, use a Group 24, marine battery. 

Battery dimensions should not exceed : 9” high 

(including post) x 12” long x 6-1/2” wide.

YOUR BATTERY BACKUP SUMP PUMP SYSTEM IS READY.

STEP 2:

Insert marine battery into battery case. Attach 

the RED and BLACK wires from the back of the 

control/alarm panel to each of the battery clamps 

provided. Then connect battery clamps to the 

battery. RED WIRE to the POSITIVE (+) terminal 

and the BLACK WIRE to the NEGATIVE (-)  

terminal.

STEP 4:

Turn the alarm switch on the control/alarm panel to the OFF position and plug the 12 volt transformer in a GFCI 

outlet. If a GFCI outlet is unavailable, have an electrician install one for you. Once proper power is supplied, turn 

the alarm switch to the on position. Then plug the primary sump pump to its power source.

BATTERY & CONTROL/ALARM PANEL ASSEMBLY

STEP 3:

Plug in the designated components to the control/

alarm panel,  A  battery backup pump,  B  the float 

switch,  C  and the 12 volt transformer.

Pre-drilled  

Mounting Holes

6-1/2”

12”

9”

B  Float Switch

Pump Cord  A

Power  C

STEP 6:

Feed the pump and float switch cords through 

the sump pump vent or utility hole and cover the 

sump with the sump cover.

Power 

Cord

Float 

Switch 

Cord

Summary of Contents for Water Ace WASBB

Page 1: ...Owner s Manual 12 Volt Battery Backup Sump Pump System General Safety 2 3 Contents Tools 4 Installation 4 6 Parts 5 Testing Operation 7 Warranty 8 TABLE OF CONTENTS...

Page 2: ...Call 1 844 394 2604 for assistance Do Not Return to Store Important Safety Instructions Carefully read and follow all safety instructions in this manual and on pump SAVE THESE INSTRUCTIONS This manua...

Page 3: ...utilate the battery Released electrolyte is harmful to the skin and eyes It may be toxic 3 The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes It is electrically conductive...

Page 4: ...ribed below to allow space for the supplied pump installation tee If discharge is 1 1 4 pipe cut off 1 1 2 of pipe If discharge is 1 1 2 pipe cut off 2 of pipe TOOLS Adjustable wrench or socket wrench...

Page 5: ...o the discharge pipe INSTALLATION Check Valve Backup Pump Suction Inlet Float Sensor Discharge Pipe 1 1 4 Tether 3 4 5 12 1 2 The top of the Battery Backup Pump should be at least 4 below the top of t...

Page 6: ...TIVE terminal and the BLACK WIRE to the NEGATIVE terminal STEP 4 Turn the alarm switch on the control alarm panel to the OFF position and plug the 12 volt transformer in a GFCI outlet If a GFCI outlet...

Page 7: ...ght Press the ON OFF switch to OFF position disconnect power to the 12 volt transformer from the GFCI outlet and disconnect the pump and float switch cords from the alarm control panel plugs Have the...

Page 8: ...tly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferable and does not apply to products used in commerc...

Reviews: