background image

4

PROBLEMS

PUMP WILL NOT START 

OR RUN  

 

 

 

 

 

 

 

 

PUMP STARTS AND 

STOPS TOO OFTEN 

 

 

 

 

PUMP WILL NOT SHUT 

OFF OR RUNS 

CONTINUOUSLY 

 

 

PUMP OPERATES BUT 

DELIVERS LITTLE OR 

NO WATER

POSSIBLE CAUSES 

CORRECTIVE ACTION

1.   Tripped home electrical breaker 

1.     Reset breaker

2.    GFCI tripped 

2.     Check for damaged wiring or moisture

3.   Low line voltage 

3.     Contact electrician

4.   Defective motor 

4.     Replace pump

5.   Dirty switch 

5.     Rinse out switch with clean water  

6.   Impeller obstructed 

6.     Remove strainer, base, and impeller    

    

 

plate (Figure1) check for debris; clean

7.    Inlet screen or strainer clogged 

7.    Clean inlet screen and debris strainer  

8.    Priming hole plugged 

8.    Clean hole, inside volute housing, with a  

    

 

pin or paper clip (Figure 1)

 

 

1.   Back flow of water from piping 

1.     Install or replace check valve

2.   Dirty switch 

2.     Rinse out switch with clean water 

3.   Pump is sitting uneven on pool or 

3.  Reposition pump so pump sits level on  

   spa cover 

 

cover  

1.    Debris in switch 

1.    Rinse out switch with clean water (Fig 2) 

2.    Discharge height exceeds capability 

2.    Reduce discharge height

 
 

1.    Impeller obstructed 

1.     Remove strainer, base, and impeller    

    

 

plate, check for debris; clean

2.    Obstructed hose 

2.     Check for kinks, reposition hose or    

    

 

check for debris

3.    Discharge height exceeds capability 

3.     Reduce discharge height

4.    Strainer clogged 

4.     Unplug pump. Remove strainer and    

    

 

rinse with clean water to remove debris

ELECTRICAL PRECAUTIONS

 

  Before servicing a pump, always shut off the main power breaker and  

 

  then unplug the pump. Make sure you are not standing in water and are 

wearing insulated protective sole shoes, under flooded conditions. Contact your local electric 

company or a qualified licensed electrician for disconnecting electrical service prior to pump 

removal

TROUBLE SHOOTING CHECKLIST  

(Caution: shut off power to pump)

Summary of Contents for SUP55PC

Page 1: ...nd be alert to the potential for personal injury Indicates a hazard which if not avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious...

Page 2: ...ideal for household water transfer Capacity Cord Solids Model HP Volt Ph Amps GPH at 0 Max Head Construction Impeller Length Pumped SUP55PC 1 4 115 1 3 3 1980 25 Thermoplastic Thermoplastic 25 1 8 AP...

Page 3: ...h pumping will begin automatically when water is lowered to lowest pumping level The pump will not run dry 6 Pump must be regularly cleaned to maintain proper operation Verify that the voltage and fre...

Page 4: ...out switch with clean water 3 Pump is sitting uneven on pool or 3 Reposition pump so pump sits level on spa cover cover 1 Debris in switch 1 Rinse out switch with clean water Fig 2 2 Discharge height...

Page 5: ...ill subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferabl...

Page 6: ...e la posibilidad de lesiones personales Indica un riesgo que si no se evita dar como resultado la muerte o lesiones graves Indica un riesgo que si no se evita podr a dar como resultado la muerte o les...

Page 7: ...para la transferencia de agua en el hogar Capacidad Longuitud S lidos Modelo HP Volt Fases Corriente GPH at 0 Altura M x Construcci n Impulsor de cable bombeados SUP55PC 1 4 115 1 3 3 1980 25 Termopl...

Page 8: ...i la bomba detecta suficiente profundidad de agua el bombeo comenzar autom ticamente cuando el agua baje al nivel de bombeo m s bajo La bomba no operar en seco 6 La bomba se debe limpiar peri dicament...

Page 9: ...uptor sucio 3 La bomba est asentada de manera desnivelada sobre la cubierta de la alberca piscina o tina de hidromasaje 1 Suciedad en el interruptor 2 La altura de descarga excede la capacidad 1 Impul...

Page 10: ...licitudes de servicio si se reciben m s de 30 d as despu s de la fecha de vencimiento de la garant a La garant a no es transferible y no se aplica a productos utilizados en aplicaciones comerciales o...

Page 11: ...t la pompe et les com posants du syst me Portez en permanence des lunettes de s curit quand vous travaillez sur des pompes Risque d explosion Le corps de pompe peut exploser si elle est utilis e comme...

Page 12: ...Mod le CV Volt Secteur Amp res GPH at 0 charge Construction Turbine cordon pomp s SUP55PC 1 4 115 1 3 3 1980 25 Thermoplastique Thermoplastique 25 1 8 13 5 342mm 9 4 239mm 13 329mm Pour liminer l eau...

Page 13: ...cordon dans une prise prot g e GFCI 5 Si la pompe d tecte une profondeur d eau suffisante le pompage va d marrer automa tiquement jusqu d tection du niveau le plus bas pour du pompage La pompe ne va p...

Page 14: ...tuyauterie 2 Interrupteur sale 3 La pompe est mal pos e sur le cou vercle de piscine ou spa 1 D bris dans l interrupteur 2 La hauteur de d chargement d passe la capacit 1 Turbine obstru e 2 Tuyau obst...

Page 15: ...ucteur proc dera une action corrective dans un d lai raisonnable Aucune demande au titre de la garantie ne sera accept e si elle est re ue plus de 30 jours apr s la date d expiration de la garantie Ce...

Page 16: ...1899 Cottage Street Ashland Ohio 44805 T l phonez 1 877 326 3561 Fax 1 877 326 1994 www ecofloproducts com Copyright 2019 ECO FLO PRODUCTS INC EF OOO1 SUP55PC 03 2019...

Reviews: