background image

OWNER’S MANUAL

 

SUP55PC

1/4 HP 

Auto Pool Cover

Utility Pump

CONTENTS:

General Safety . . . . . . . . . . . . . . . . . . . . 1
Specifications & Performance . . . . . . . . 2
Installation  . . . . . . . . . . . . . . . . . . . . . . .3 
Troubleshooting . . . . . . . . . . . . . . . . . . . 4
Warranty . . . . . . . . . . . . . . . . . . . . . . . . .5 

BEFORE YOU START

A utility pump is an electrical 

device designed to operate in 

inherently wet environments.

ALWAYS USE EXTREME 

CAUTION

 

when installing or 

maintaining this product.

 

®

Carefully read and follow all safety  

instructions in this manual and on pump. 
SAVE THESE INSTRUCTIONS – This manual 

contains important instructions that should be 

followed during installation, operation, and  

maintenance of the product.  

Save this manual for future reference.
Safety Labels

 

 

         This is the safety alert symbol. When you 

see this symbol on your pump or in this manual, 

look for one of the following signal words and be 

alert to the potential for personal injury!
 

 

Indicates a hazard which, if 

not avoided, will result in death or serious injury.
 

 

Indicates a hazard which, 

if not avoided, could result in death or serious 

injury.
 

 

Indicates a hazard which, if 

not avoided, could result in minor or moderate 

injury.

NOTICE

 indicates practices not related to 

personal injury.
Keep safety labels in good condition. Replace 

missing or damaged safety labels.

General Safety

 

 

Risk of burns. Do not 

touch an operating motor. Motors are de-

signed to operate at high temperatures. To 

avoid burns when servicing pump, allow it to 

cool for 20 minutes after shut-down before 

handling.
Do not allow pump or any system compo-

nent to freeze. To do so will void warranty.
Pump water only with this pump.
Periodically inspect pump and system com-

ponents.
Wear safety glasses at all times when work-

ing on pumps.
 

 

Risk of explosion. Pump 

body may explode if used as a booster 

pump.

IMPORTANT SAFETY INSTRUCTIONS

Summary of Contents for SUP55PC

Page 1: ...nd be alert to the potential for personal injury Indicates a hazard which if not avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious...

Page 2: ...ideal for household water transfer Capacity Cord Solids Model HP Volt Ph Amps GPH at 0 Max Head Construction Impeller Length Pumped SUP55PC 1 4 115 1 3 3 1980 25 Thermoplastic Thermoplastic 25 1 8 AP...

Page 3: ...h pumping will begin automatically when water is lowered to lowest pumping level The pump will not run dry 6 Pump must be regularly cleaned to maintain proper operation Verify that the voltage and fre...

Page 4: ...out switch with clean water 3 Pump is sitting uneven on pool or 3 Reposition pump so pump sits level on spa cover cover 1 Debris in switch 1 Rinse out switch with clean water Fig 2 2 Discharge height...

Page 5: ...ill subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warranty is not transferabl...

Page 6: ...e la posibilidad de lesiones personales Indica un riesgo que si no se evita dar como resultado la muerte o lesiones graves Indica un riesgo que si no se evita podr a dar como resultado la muerte o les...

Page 7: ...para la transferencia de agua en el hogar Capacidad Longuitud S lidos Modelo HP Volt Fases Corriente GPH at 0 Altura M x Construcci n Impulsor de cable bombeados SUP55PC 1 4 115 1 3 3 1980 25 Termopl...

Page 8: ...i la bomba detecta suficiente profundidad de agua el bombeo comenzar autom ticamente cuando el agua baje al nivel de bombeo m s bajo La bomba no operar en seco 6 La bomba se debe limpiar peri dicament...

Page 9: ...uptor sucio 3 La bomba est asentada de manera desnivelada sobre la cubierta de la alberca piscina o tina de hidromasaje 1 Suciedad en el interruptor 2 La altura de descarga excede la capacidad 1 Impul...

Page 10: ...licitudes de servicio si se reciben m s de 30 d as despu s de la fecha de vencimiento de la garant a La garant a no es transferible y no se aplica a productos utilizados en aplicaciones comerciales o...

Page 11: ...t la pompe et les com posants du syst me Portez en permanence des lunettes de s curit quand vous travaillez sur des pompes Risque d explosion Le corps de pompe peut exploser si elle est utilis e comme...

Page 12: ...Mod le CV Volt Secteur Amp res GPH at 0 charge Construction Turbine cordon pomp s SUP55PC 1 4 115 1 3 3 1980 25 Thermoplastique Thermoplastique 25 1 8 13 5 342mm 9 4 239mm 13 329mm Pour liminer l eau...

Page 13: ...cordon dans une prise prot g e GFCI 5 Si la pompe d tecte une profondeur d eau suffisante le pompage va d marrer automa tiquement jusqu d tection du niveau le plus bas pour du pompage La pompe ne va p...

Page 14: ...tuyauterie 2 Interrupteur sale 3 La pompe est mal pos e sur le cou vercle de piscine ou spa 1 D bris dans l interrupteur 2 La hauteur de d chargement d passe la capacit 1 Turbine obstru e 2 Tuyau obst...

Page 15: ...ucteur proc dera une action corrective dans un d lai raisonnable Aucune demande au titre de la garantie ne sera accept e si elle est re ue plus de 30 jours apr s la date d expiration de la garantie Ce...

Page 16: ...1899 Cottage Street Ashland Ohio 44805 T l phonez 1 877 326 3561 Fax 1 877 326 1994 www ecofloproducts com Copyright 2019 ECO FLO PRODUCTS INC EF OOO1 SUP55PC 03 2019...

Reviews: