background image

For parts or assistance, call ECO-FLO Customer Service at 1-877 326-3561

8

CORRECTIVE ACTION

Replace fuse or reset circuit breaker.
DISCONNECT POWER; Replace starting switch
Refer to instructions on wiring (Page 9). DISCONNECT POWER; check and 
tighten all wiring. (WARNING symbol) Hazardous voltage. Capacitor voltage may 
be hazardous. To discharge capacitor, hold insulated handle screwdriver BY THE 
HANDLE and short capacitor terminals together. Do not touch metal screwdriver 
blade or capacitor terminals. If in doubt, consult a qualified electrician.

Refer to instructions on wiring.
Check with power company. Install heavier wiring if wire size is too small (See 
Electrical/Wiring Chart)
See section below on too frequent cycling.

In new installation:                                                                                              
1. Re-prime according to instructions.                                                              
2. Check all connections on suction line and AVC with shaving cream.      
3. Replace foot valve or check valve.
 
In installation already in use: 
1. Check all connections on suction line and shaft seal.                               
2. Lower suction line into water and re-prime. If receding water level in              
  well exceeds 25’ (7.6M0, a deep well pump is needed.
3. Replace faulty valve.
Clean foot valve or strainer
Clean ejector or impeller.
Replace check valve or foot valve.
Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
Raise foot valve and/or strainer above bottom of water source. Clean foot valve  
and strainer.
A deep well jet will be needed if your well is more than 25’ (7.6M0 depth to 
water.
 
A new nozzle and venturi combination may be needed.
Replace with plastic pipe where possible, otherwise with new steel pipe.

Use larger piping.

DISCONNECT POWER; adjust or replace pressure switch

Close faucets
Clean venturi, nozzle or impeller
Drain tank to air volume control port. Check AVC for defects. Check all 
connections for leaks.
Check connections.
Replace foot valve.
Adjust or replace pressure switch.
DISCONNECT POWER and open faucets until all pressure is relieved. Using tire 
pressure gauge, check air pressure in tank at valve stem located on the tank. 
If less than pressure switch cut in setting (30-50 PSI), pump air into tank from 
outside source until air pressure is 2 PSI less than cut-in setting of switch. 
Check air valve for leaks (use soapy solution) and replace core if necessary.
 
When pump has picked up prime, it should pump solid water with no air.
Suction pipe is sucking air. Check joints for leaks with shaving cream.
Consult factory about installing a sleeve in the well.
Lower foot valve if possible, otherwise restrict pump discharge.

TROUBLE SHOOTING

POSSIBLE  CAUSE(S)

 

Fuse is blown or circuit breaker tripped
Starting switch is defective
 
 
Wires at motor are loose, disconnected, or wired 
incorrectly

 
Motor is wired incorrectly

Voltage is too low
 

Pump cycles too frequently
 
Pump  in  new  installation  did  not  prime  due  to:                                                                      
1. Pipes were not filled with water 
2. Air leaks                                                                 
3. Leaking foot valve or check valve
 
Pump  has  lost  prime  through:                                                                   
1. Air leaks                                                             
2. Water level below suction pipe inlet
 
3. Faulty check or foot valve.
Foot valve or strainer is plugged
Ejector or impeller is plugged
Check valve or foot valve is stuck shut
Pipes are frozen
Foot valve and/or strainer are buried in sand or mud
 
Water level is too low for shallow well setup to 
deliver water
 
Water level in well is lower than estimated.
Steel piping (if used) is corroded or limed, causing 
excess friction
Piping is too small in size
 
Pressure switch is out of adjustment or contacts 
are welded together
Faucets have been left open
Venturi, nozzle or impeller is clogged
Standard pressure tank is waterlogged and has no 
air cushion
Pipes leak
Foot valve leaks
Pressure switch is out of adjustment  
Air charge too low in pre-charged tank

 
Pump is not primed
Leak in suction side of pump
Well is gaseous
Intermittent over-pumping of well. (Water drawn 
down below foot valve.)

SYSTEM

 

 

Motor will not run

 
Motor runs hot and 
overload kicks off

 
 

 
Motor runs but no 
water  is  delivered*                                                                                                                                       
                                                       

*Stop pump; then check 
prime before looking for 
other causes. Unscrew 
priming plug and see if 
water is in priming hole

Pump does not deliver 
water to full capacity 
(Also check point 3 im-
mediately above)

 
 

Pump delivers water but 
does not shut off or pump 
cycles too frequently

 
 

Air spurts from faucets

Summary of Contents for SHALLOW WELL

Page 1: ...Owner s Manual Plastic Shallow Jet Pumps General Safety 2 Installation 3 5 Electrical 6 Operation 7 Troubleshooting 8 Repair Parts 9 Jet Tank Assembly 10 Warranty 11 TABLE OF CONTENTS...

Page 2: ...injury Indicates a hazard which if not avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious injury Indicates a hazard which if not a...

Page 3: ...e to the well as possible 2 Assemble the foot valve strainer and well pipe Make sure that the foot valve works freely 3 Lower the pipe into the well until the strainer is five feet above the bottom of...

Page 4: ...is not equipped with one 5 Install a priming tee priming plug and pressure gauge to pump s discharge port Connect the pipe from the well to the pump s suction port using the fewest possible fittings...

Page 5: ...r to prevent the pump from sucking air 5 Install a priming tee priming plug and pressure gauge to pump s discharge port Connect the pipe from the well to the pump s suction port using the fewest possi...

Page 6: ...tor for the proper electrical source voltage i e 115V or 230V see the wiring diagrams in this manual or under the cover of the motor Ensure to ground the pressure switch to the motor Disconnect power...

Page 7: ...om the tee and fill the suction piping 2 Replace all fill plugs Leave the control valve open in a shallow well installation the control valve always stays open 3 Turn electric power on 4 Start the pum...

Page 8: ...the tank If less than pressure switch cut in setting 30 50 PSI pump air into tank from outside source until air pressure is 2 PSI less than cut in setting of switch Check air valve for leaks use soapy...

Page 9: ...r 1 2 HP 5 1 EFSWJ7P05 Diffuser for 3 4 HP 1 EFSWJ7P05 Diffuser for 1 HP 1 EFSWJ5P06 Impeller for 1 2 HP 6 1 EFSWJ7P06 Impeller for 3 4 HP 1 EFSWJ7P06 Impeller for 1 HP 7 1 EFSWJ5P07 Seal 8 1 EFSWJ5P0...

Page 10: ...ump motor on pressure 30 PSI pounds per square inch b Pump motor off pressure 50 PSI 4 Once you know the turn on off pressures alter the air pressure in the empty pre charge tank to 2 two PSI below th...

Page 11: ...e discovery or any alleged defect Manufacturer will subsequently take corrective action as promptly as reasonably pos sible No requests for service will be accepted if received more than 30 days after...

Page 12: ...ice at 1 877 326 3561 12 Manuel des propri taires Pompes en plastique de jet de surface S curit g n rale 13 Installation 14 16 Electrique 17 Op ration 18 d pannage 19 Parts de r paration 20 Assembl e...

Page 13: ...des linformations de s curit 1 Evite les br lures de pression l explosion 2 vite un choc lectrique Remplissez la pompe d eau Assurez vous que le corps de pompe est rempli d eau pour d charger Les inst...

Page 14: ...du niveau de l eau du puits 4 Installez un joint sanitaire de puits 5 Installer un tee d amor age le bouchon d amor age et la jauge de pression au port de succion de la pompe Connectez le tuyau du pui...

Page 15: ...age le bouchon d amor age et la jauge de pression au port de succion de la pompe Connectez le tuyau du puits au port de succion de la pompe en utilisant le moins possible les installations surtout le...

Page 16: ...pieds du fond du puits Il devrait gale ment tre au moins 10 pieds au dessous du niveau de l eau du puits afin d viter que la pompe ne suce pas de l air 5 Installer un tee d amor age le bouchon d amor...

Page 17: ...ou sous le couvercle du moteur Assurez vous de relier le commutateur de pression au moteur Coupez l alimentation avant de travailler sur la pompe le moteur l interrupteur de pression ou le c blage Le...

Page 18: ...sque la pression attaint 50 PSI Marchez la pompe travers un ou deux cycles complets afin de v rifier le bon fonctionnement Cela permettra galement de nettoyer le syst me de la salet et de l chelle d l...

Page 19: ...e r servoir Si moins de commutateur de pres sion de coupure dans la mise 30 50 PSI la pompe de l air dans le r servoir de source ext rieure jusqu ce que la pression de l air est de 2 PSI moins de coup...

Page 20: ...P05 Diffsuer pour 1 2 HP 5 1 EFSWJ7P05 Diffsuer pour 3 4 HP 1 EFSWJ7P05 Diffsuer pour 1 HP 1 EFSWJ5P06 Impelleur pour 1 2 HP 6 1 EFSWJ7P06 Impelleur pour 3 4 HP 1 EFSWJ7P06 Impelleur pour 1 HP 7 1 EFS...

Page 21: ...a pression 30 PSI livres par pouce carr b la pompe moteur hors de la pression 50 PSI 4 Une fois que vous connaissez les pressions ouvertes ferm es modifiez la pression d air dans le r servoir de pr ch...

Page 22: ...rable et ne s applique pas aux produits utilis s dans des applications commerciales de location Les termes et les conditions g n raux Les limitations de recours Vous devez payer tous les travaux et l...

Page 23: ...ario Bombas Jet poco profundos de pl stico Seguridad General 24 Instalaci n 25 27 El ctrico 28 Operaci n 29 Soluci n de Problemas 30 Piezas de Repuesto 31 Asamblea Chorro Tanque 32 Garant a 33 Tabla d...

Page 24: ...se evita provocar la muerte o lesiones graves indica un peligro que si no se evita podr a causar la muerte o lesiones graves indica un riesgo que si no puede evitarse puede provocar lesiones leves o...

Page 25: ...ro y la tuber a del pozo Aseg rese de que la v lvula de retenci n funcione libremente 3 Baje la tuber a hacia el pozo hasta que el filtro se en cuentre a cinco pies sobre el fondo del pozo Tambi n deb...

Page 26: ...tap n de cebado y el man metro de la bomba del puerto de descarga Conectar el tubo desde el pozo hasta el puerto de succi n de la bomba utilizando los menor n mero de conex iones posibles especialmen...

Page 27: ...e encuen tre a cinco pies sobre el fondo Tambi n debe ser de al menos 10 metros por debajo del nivel de agua con el fin de evitar que la bomba aspire aire 5 Instale una T de cebado tap n de cebado y e...

Page 28: ...ajo la cubierta del motor Aseg rese de poner a tierra el interruptor de presi n al motor Ensure to ground the pressure switch to the motor Desconecte la alimentaci n antes de trabajar en la bomba el m...

Page 29: ...l pozo est lleno Si tambi n ha instalado una camiseta cebado en la tuber a de succi n retire el enchufe de la camiseta y llenar la tuber a de succi n 2 Reemplace todos los tapones de llenado Deje la v...

Page 30: ...ador aislado POR EL MANGO y terminales corto condensador juntos No toque los terminales de cuchilla destornillador o conden sadores de metal En caso de duda consulte a un electricista calificado Consu...

Page 31: ...or 1 2 HP 5 1 EFSWJ7P05 Difusor por 3 4 HP 1 EFSWJ7P05 Difusor por 1 HP 1 EFSWJ5P06 Impulsor por 1 2 HP 6 1 EFSWJ7P06 Impulsor por 3 4 HP 1 EFSWJ7P06 Impulsor por 1 HP 7 1 EFSWJ5P07 Sello 8 1 EFSWJ5P0...

Page 32: ...presi n 30 PSI libras por pulgada cuadrada b Bomba motor de presi n 50 PSI 4 Una vez que sepa el giro en las presiones de activaci n desactivaci n alterar la presi n de aire en el tanque de pre carga...

Page 33: ...No se aceptar n solicitudes de servicio si se recibe m s de 30 d as despu s del vencimiento de la garant a La garant a no es transferible y no se aplica a productos usados en aplicaciones comerciales...

Reviews: