ECO Charge BMM Operator/Installer Manual Download Page 6

6

DC Supply & Voltage
Midpoint Sensor

The  DC  Supply  wires  are 
terminated  with  ring  terminals 
for  easy  fastening  to  the 
battery 

with 

the 

supplied 

screws. The positive (RED) and 
negative  (BLACK)  wires  should 
be  fastened  to  the  top  of  their 
respective 

battery 

terminal 

posts.  The  Midpoint  Voltage 
(WHITE) 

wire 

should 

be 

fastened  to  strapping  or  a 
terminal  as  close  as  possible 
to  the  voltage  midpoint  of
the  battery.  It  is  recommended 
to 

coat 

wire 

terminations 

with  corrosion  inhibitor  before 
installation.

Temperature Sensor

The ideal location for the BMM 
temperature  sensor  is  between 
the  cells  at  the  center  of  the 
battery.  Depending  on  the 
battery  type  and  construction, 
this  may  not  be  practical.  The 
alternative location is cable tied 
to  the  underside  of  a  segment 
of lead strapping. An additional 
temperature sensor is built-in to 
the BMM module.

Installation

 - continued

Summary of Contents for BMM

Page 1: ...Battery Monitoring Module BMM Operator Installer Manual...

Page 2: ...n Be aware of battery fumes and electrolyte Do not dispose of batteries in the garbage Electrical hazard exists inside the charger do not remove the side cover Always recycle lead acid batteries Batte...

Page 3: ...peration 11 LED Function Indicator 11 Voltage Imbalance Monitoring 12 Water Level Monitoring 13 Troubleshooting 14 Maintenance 15 Service Warranty 16 Specifications 17 BMM Serial Number BMM Part Numbe...

Page 4: ...Voltage Sensor Module Housing Battery Monitoring Module BMM 2 This guide covers the installation of a BMM and configuration of a BMM and associated XHF Series Charger For instructions on the advanced...

Page 5: ...he negative battery terminal Alignment of the toroid should be made so that the cable exits the toroid away from the battery terminal Keep at least 8in 20cm clearance between the toroid and the positi...

Page 6: ...or a terminal as close as possible to the voltage midpoint of the battery It is recommended to coat wire terminations with corrosion inhibitor before installation Temperature Sensor The ideal locatio...

Page 7: ...on of the electrolyte sensor requires care and consideration of the cell s internal construction If not required the electrolyte sensor should be removed from the BMM by cutting the brown sensor wire...

Page 8: ...be used with the BMM Required for configuration The BMM installed on the battery A XHF Series Charger Standard A to Mini B USB cable PC or laptop running Windows Vista or later with Charger Interface...

Page 9: ...template s parameters To load the configuration parameters into the BMM module click Write Configuration The BMM configuration can be confirmed by clicking Read Configuration and checking that the co...

Page 10: ...n tab and ensure the tab is visible From the Configuration Template drop down list choose the option APC Enabled Ensure the adjacent drop down lists are appropriate for charger type and AC supply Clic...

Page 11: ...nected to the BMM Operation of the BMM module is automated once installed and configured Connect the BMM equipped battery to an APC enabled XHF Series charger The charger must display APC Enabled for...

Page 12: ...nce following the current charge if connected or following the next completed charge Should the midpoint voltage imbalance persist further equalizations will be scheduled Repeated Voltage Imbalance al...

Page 13: ...s charger display configured for BMM operation Initiate a top up of the battery following a charge provided both the XHF series charger and the battery are fitted with an auto watering system Enabling...

Page 14: ...g 0 5V outside the half battery voltage The BMM automatically schedules an equalize charge on this alarm occurrence Regular occurrence indicates poor battery condition or incorrect installation Check...

Page 15: ...battery acid Routine checks on the condition of DC Supply and Midpoint Voltage terminals should be made and any accumulated corrosion removed according to the battery maintenance documentation Typical...

Page 16: ...r repaired in any way which may affect the performance or reliability of operation sustained damage by power surges or electrical storms or sustained shipping damage or repaired by any unauthorized re...

Page 17: ...Range 5 F to 122 F max output power is derated above 122 F Storage Temp 68 F to 158 F Humidity 5 95 RH non condensing Bluetooth Specifications Class 1 Bluetooth 2 0 Contains FCCID T9JRN41 3 The Bluet...

Page 18: ...Notes...

Page 19: ......

Page 20: ...Enatel Motive Power Ltd 66 Treffers Road Christchurch 8042 New Zealand Ph 64 3 366 4550 Fax 64 3 366 0884 info enatel mp com www enatel mp com Battery Monitoring Module BMM Operator Installer Drawing...

Reviews: