____________________________________________________________________________________ 

13 

2. A white mist coming out from the indoor unit 

 

A white mist may generate due to a large temperature difference between air inlet and air outlet on COOL 
mode in an indoor environment that has a high relative humidity. 

 

A white mist may generate due to moisture generated from defrosting process when the air conditioner 
restarts in HEAT mode operation after defrosting. 

 

3. Low noise of the air conditioner 

 

You may hear a low hissing sound when the compressor is running or has just stopped running. This 
sound is the sound of the refrigerant flowing or coming to a stop. 

 

You can also hear a low "squeak" sound when the compressor is running or has just stopped running. 
This is caused by heat expansion and cold contraction of the plastic parts in the unit when the 
temperature is changing. 

 

A noise may be heard due to louver restoring to its original position when power is first turned on. 

 

4.  Dust is blown out from the indoor unit.  

This is a normal condition when the air conditioner has not been used for a long time or during first use of the 
unit.  

 

5.  A peculiar smell comes out from the indoor unit.  

This is caused by the indoor unit giving off smells permeated from building material, from furniture, or smoke.  

 

6.  The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and heating models 

only) mode.

 

 

When indoor temperature reaches the temperature setting on air conditioner, the compressor will stop 
automatically, and the air conditioner turns to FAN only mode. The compressor will start again when the 
indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating models only) to the 
set point. 

 

7.

 

Dripping water may generate on the surface of the indoor unit when cooling in a high relatively 
humidity (relative humidity higher than 80%)

. Adjust the horizontal louver to the maximum air outlet 

position and select HIGH fan speed.  

 

8.  Heating mode (For cooling and heating models only)  

The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating 
operation. When the outside temperature falls, heat drawn in by the air conditioner and will decrease 
accordingly. At the same time, heat loading of the air conditioner increases due to larger difference between 
indoor and outdoor temperature. If a comfortable temperature can't be achieved by the air conditioner, we 
suggest you use a supplementary heating device.  

 

9.  Auto-restart function 

Power failure during operation will stop the unit completely. 
For the unit without Auto-restart feature, when the power restores, the OPERATION indicator on the indoor 
unit starts flashing. To restart the operation, push the ON/OFF button on the remote controller. For the unit 
with Auto-restart feature, when the power restores, the unit restarts automatically with all the previous settings 
preserved by the memory function. 

 

10.  Lightning or a car wireless telephone operating nearby may cause the unit to malfunction

. Disconnect 

the unit with power and then re-connect the unit with power again. Push the ON/OFF button on the remote 
controller to restart operation. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ECO120SD

Page 1: ...dance with the national wiring standards by authorized personnel only Contact the authorised service technician for repair or maintenance of this unit User Manual Register your air conditioner Model i...

Page 2: ...ogy Your new EcoAir high efficiency room air conditioner will give you many years of dependable service Many features have been built into your EcoAir air conditioner to assure quiet operation the bes...

Page 3: ...ing tips If you review the chart of Troubleshooting Tips first you may not need to call for service CAUTION Contact an authorised service technician for repair or maintenance of this unit Contact the...

Page 4: ...ic household waste For disposal A Contact your local council for disposal B The manufacture will take back the old appliance for disposal when you replace with a new product C Old products contain val...

Page 5: ...p environment It may cause electric shock Do not allow water to run into electric parts It may cause failure of machine or electric shock It may cause electric shock or fire If the power cord is damag...

Page 6: ...ing it out Failure to do so may cause electric shock and damage Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure If bracket is damaged there is co...

Page 7: ...arts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading...

Page 8: ...troller holder 11 Remote controller Outdoor Unit 12 Connecting cable 13 Connective pipe 14 Stop valve DISPLAY WINDOW DEFROST operation display Displayed when the air conditioner starts defrosting auto...

Page 9: ...DRY mode Before select the function it is recommended to run the air conditioner under Cooling operation for about half an hour Once the Self Clean function is activated all TIMER settings will be can...

Page 10: ...neven room temperatures Adjust the horizontal louver using the remote controller Adjust the vertical louver manually or by the remote controller depending on the models To set the vertical air flow Up...

Page 11: ...t with horizontal louvre in closed position When the air conditioner is connected to power initial power the horizontal louvre may generate a sound for 10 seconds this is a normal operation Optimal op...

Page 12: ...y operation During the dry operation if the room temperature is lower than 10 C the compressor stops operation and restarts until the room temperature is above 12 C Operation Tips The following events...

Page 13: ...he compressor will stop automatically and the air conditioner turns to FAN only mode The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode For cooling an...

Page 14: ...or similar solvents for cleaning These may cause the plastic surface to crack or deform Cleaning the air filter NOTE Supply power must be disconnected before cleaning the indoor unit A clogged air fi...

Page 15: ...t collector with mild detergent or water and dry in the sunlight for two hours Before re install the Plasma dust collector check whether the Y Series or support frame is damaged or not Install the air...

Page 16: ...ecurely in wall receptacle Fuse may have blown Replace the fuse Battery in Remote controller may Replace the battery have been exhausted The time you have set with timer Wait or cancel timer setting i...