ENGLISH
Translation of the German original user manual
28
2.
Open the steam valve and release the steam. Then close it again.
3.
Let the machine cool down to room temperature.
Follow the steps as indicated below:
1.
Brew group in the beginning.
2.
Use a flat screwdriver to pry out
the shower screen and the group
gasket.
3.
The shower screen and the
gasket are now nearly removed.
4.
Remove the shower screen and
the gasket completely.
5.
Keep the new spare parts ready
at hand (the rounded side of the
group gasket with ECM print
facing upwards to the brew
group).
6.
Clean the brew group with a
brush.
Lock the shower screen firmly
into the gasket.
7.
Insert the shower screen into the
brew group.
8.
Take the portafilter without filter.
9.
Clamp the portafilter into the
brew group.
10.
Then, move the portafilter until
the shower screen is locked
firmly into the gasket.
11.
Now you can easily lock the
portafilter into place.
12.
The group is ready for use.
The machine can be used again, as described in chapter 6 of the user manual.