19
CURRENT NID
= 0x10 (16)
PRODUCT CODE
= 0x03 (3)
REVISION NUMBER
= 0x03 (3)
SERIAL NUMBER
= 0x192 (402)
NEW NID
= 0x1A (26)
MESSAGE SENT
MODULE REPLY
Example: Change the NID for the
only CANopen module
on the CAN bus.
CURRENT NID
= 0x10 (16)
NEW NID
= 0x1A (26)
MESSAGE SENT
MODULE REPLY
8.6
Changing the TPDO Broadcast Rate
The data broadcast rate can be programmed from 5 ms to 65535 ms and applies to all TPDOs
that have been enabled (see section 8.7). It is an unsigned 16bit integer (2 bytes) written least
significant byte (LSB) first (Intel format) to OD address 0x1800, subindex 0x05. The format of
the SDO Write to the LambdaCAN module is as follows:
CANid
byte 0
byte 1
byte 2
byte 3
byte 4
byte 5
byte 6 byte 7
0x600+NID
0x2B
0x00
0x18
0x05
Broadcast
rate lo
Broadcast
rate hi
Example: Set TPDO broadcast rate to 500 ms (0x01F4) for the module with NID = 0x0F (15).
CAN id
byte 0
byte 1
byte 2
byte 3
byte 4
0x00
0x80
0x10
0x7E5
0x04
0x00
0x7E5
0x40
0xC6
0x01
0x00
0x00
0x7E5
0x41
0x03
0x00
0x00
0x00
0x7E5
0x42
0x03
0x00
0x00
0x00
0x7E5
0x43
0x92
0x01
0x00
0x00
0x7E5
0x11
0x1A
0x7E5
0x04
0x00
0x00
0x82
0x1A
CAN id
byte 0
byte 1
0x7E4
0x44
0x7E4
0x11
0x00
CAN id
byte 0
byte 1
0x00
0x80
0x10
0x7E5
0x40
0x01
0x7E5
0x11
0x1A
0x7E5
0x04
0x00
0x00
0x82
0x1A
CAN id
byte 0
byte 1
0x7E4
0x44
0x7E4
0x11
0x00
Summary of Contents for NH3CAN
Page 4: ...4...
Page 7: ...7 P N 02 12 P N 06 07...